Ventilation appliances
  
   A   L 400 120
 
   Stainless  steel
  Width  120  cm
  Air extraction/recirculation with remote 
fan unit AR 400/401/403/413
  Motorless
     A   L 400 190
 
   Stainless  steel
  Width  90  cm
  Air extraction/recirculation with remote 
fan unit AR 400/401/403/413
  Motorless
          Installation  accessories
    A   A 010 410
 
  Air exhaust grille recirculation mode
   Stainless  steel  coloured,  90  cm, 
including installation fittings, height 
adjustable.
     A   A 409 400
 
  Furniture support 86 cm for table 
ventilation 106/90 cm
   Recommended as bearer for the 
worktop, instead of a cabinet frame.
     A   A 409 430
 
  Furniture support 116 cm for table 
ventilation 136/120 cm
   Recommended as bearer for the 
worktop, instead of a cabinet frame.
     A   D 754 045
 
  Connection piece for 2 cylindrical 
ducts DN 150
   Fitting AL 400, front or back side.
     A   D 854 043
 
     Connection  piece  for  2  flat  ducts 
DN 150
  Fitting AL 400, bottom side.
     A   D 854 045
 
  Connection piece for 2 flat ducts 
DN 150
   Fitting AL 400, front or back side.
     Z   B 020 090
 
  Ventilation grille stainless steel
   Extension piece for 30 mm, necessary 
for height adjustment.
  Order 1 for height adjustment of 
31-60 mm.
Order 2 for height adjustment of 
61-70 mm.
           Table  ventilation
  A   L 400 
 
–    Telescopic  table  ventilation  for 
combination with all Gaggenau 
cooktops, completely retractable 
when not in use
 
–   Dimmable LED light for illumination 
of the whole cooktop
 
–   Precision crafting of 3 mm stainless 
steel
 
–   For surface installation with a 
visible edge or for flush installation
 
–   Can be combined perfectly with 
other Vario appliances of the 400 
series
     Output
  Maximum air output in combination 
with remote fan units s. table remote 
fan units on page 252/253.
  Sound power level depends on the 
built-in situation.
    Features
  3 electronically controlled output 
levels.
  Intensive  mode.
  Interval  ventilation.
  Run-on  function.
  Grease filter saturation indicator.
  Cartridge-type  filter,  dishwasher-safe.
  LED  light.
  Spare covers for closing air outlets.
  No duct connection piece included.
    Planning  notes
  AL 400 120 (AL 400 190)
For operation with 4 (3) Vario 200 
series cooktops, 3 (2) Vario 400 series 
cooktops or a cooktop configuration of 
up to 120 (92 cm) wide.
  Max. output of induction and glass 
ceramic cooktops 12 kW.
  In combination with the cooktop 
CI 490, installation in 60 cm deep 
worktops is possible.
  Operation of Vario cooking appliances 
only possible without appliance cover.
  Installation is possible in worktops 
made of stone, synthetics or solid 
wood. Heat resistance and watertight 
sealing of the cut edges must be 
observed. Concerning other materials 
please consult the worktop manufac-
turer.
  If the remote fan unit is installed within 
the bottom cabinet and if combined 
with VK or VF ensure accessibility to 
the outlets.
  The remaining surface of the worktop 
(min. 50 mm) between the cut-outs 
must be reinforced with a support. It is 
recommended to use furniture support 
AA 409 400/430.
  Ovens that do not exceed the maximum 
allowed cabinet temperature can be 
combined with the table ventilation if 
built-in situation permits.
  Recommendation for stainless steel 
parts to match hood that have to be 
welded and polished: brushed 
grain 280.
  Surfaces: Stainless steel 1.4301, 
ground and brushed IIIC.
  For  air  recirculation:
  The exhaust outlet in the plinth should 
be as large as possible to minimise 
draughts.
  The location of the exhaust outlet in the 
plinth is consumer-defined. Minimum 
cross-section 720 cm².
  To avoid smoke when frying/grilling 
refer to the manuals of VR/VP.
  For  air  extraction:
  For maximum duct lengths use 
Gaggenau flat rectangular ducts AD 8… 
or Naber-System Compair flow. Other 
flat ducts are not permitted!
  Duct connection front or backwards: 
2 ducts DN 150 cylindrical or flat 
rectangular duct. Downwards 2 ducts 
DN 150 flat rectangular duct 
(installation accessory).
  When installing a ventilation hood with 
air extraction mode and a chimney-
vented fireplace, the hood's power 
supply line needs a suitable safety 
switch.
    Connection
  Connecting cable 1.7 m with plug.