Gaggenau AL400721 Brochure
200
Ventilation appliances
A L 400 120
Stainless steel
Width 120 cm
Air extraction/recirculation with remote
fan unit AR 400/401/403/413
Motorless
Width 120 cm
Air extraction/recirculation with remote
fan unit AR 400/401/403/413
Motorless
A L 400 190
Stainless steel
Width 90 cm
Air extraction/recirculation with remote
fan unit AR 400/401/403/413
Motorless
Width 90 cm
Air extraction/recirculation with remote
fan unit AR 400/401/403/413
Motorless
Installation accessories
A A 010 410
A A 010 410
Air exhaust grille recirculation mode
Stainless steel coloured, 90 cm,
including installation fittings, height
adjustable.
Stainless steel coloured, 90 cm,
including installation fittings, height
adjustable.
A A 409 400
Furniture support 86 cm for table
ventilation 106/90 cm
Recommended as bearer for the
worktop, instead of a cabinet frame.
ventilation 106/90 cm
Recommended as bearer for the
worktop, instead of a cabinet frame.
A A 409 430
Furniture support 116 cm for table
ventilation 136/120 cm
Recommended as bearer for the
worktop, instead of a cabinet frame.
ventilation 136/120 cm
Recommended as bearer for the
worktop, instead of a cabinet frame.
A D 754 045
Connection piece for 2 cylindrical
ducts DN 150
Fitting AL 400, front or back side.
ducts DN 150
Fitting AL 400, front or back side.
A D 854 043
Connection piece for 2 flat ducts
DN 150
Fitting AL 400, bottom side.
DN 150
Fitting AL 400, bottom side.
A D 854 045
Connection piece for 2 flat ducts
DN 150
Fitting AL 400, front or back side.
DN 150
Fitting AL 400, front or back side.
Z B 020 090
Ventilation grille stainless steel
Extension piece for 30 mm, necessary
for height adjustment.
Order 1 for height adjustment of
31-60 mm.
Order 2 for height adjustment of
61-70 mm.
Extension piece for 30 mm, necessary
for height adjustment.
Order 1 for height adjustment of
31-60 mm.
Order 2 for height adjustment of
61-70 mm.
Table ventilation
A L 400
– Telescopic table ventilation for
combination with all Gaggenau
cooktops, completely retractable
when not in use
cooktops, completely retractable
when not in use
– Dimmable LED light for illumination
of the whole cooktop
– Precision crafting of 3 mm stainless
steel
– For surface installation with a
visible edge or for flush installation
– Can be combined perfectly with
other Vario appliances of the 400
series
series
Output
Maximum air output in combination
with remote fan units s. table remote
fan units on page 252/253.
Sound power level depends on the
built-in situation.
with remote fan units s. table remote
fan units on page 252/253.
Sound power level depends on the
built-in situation.
Features
3 electronically controlled output
levels.
Intensive mode.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Cartridge-type filter, dishwasher-safe.
LED light.
Spare covers for closing air outlets.
No duct connection piece included.
levels.
Intensive mode.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Cartridge-type filter, dishwasher-safe.
LED light.
Spare covers for closing air outlets.
No duct connection piece included.
Planning notes
AL 400 120 (AL 400 190)
For operation with 4 (3) Vario 200
series cooktops, 3 (2) Vario 400 series
cooktops or a cooktop configuration of
up to 120 (92 cm) wide.
Max. output of induction and glass
ceramic cooktops 12 kW.
In combination with the cooktop
CI 490, installation in 60 cm deep
worktops is possible.
Operation of Vario cooking appliances
only possible without appliance cover.
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must be
observed. Concerning other materials
please consult the worktop manufac-
turer.
If the remote fan unit is installed within
the bottom cabinet and if combined
with VK or VF ensure accessibility to
the outlets.
The remaining surface of the worktop
(min. 50 mm) between the cut-outs
must be reinforced with a support. It is
recommended to use furniture support
AA 409 400/430.
Ovens that do not exceed the maximum
allowed cabinet temperature can be
combined with the table ventilation if
built-in situation permits.
Recommendation for stainless steel
parts to match hood that have to be
welded and polished: brushed
grain 280.
Surfaces: Stainless steel 1.4301,
ground and brushed IIIC.
For operation with 4 (3) Vario 200
series cooktops, 3 (2) Vario 400 series
cooktops or a cooktop configuration of
up to 120 (92 cm) wide.
Max. output of induction and glass
ceramic cooktops 12 kW.
In combination with the cooktop
CI 490, installation in 60 cm deep
worktops is possible.
Operation of Vario cooking appliances
only possible without appliance cover.
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must be
observed. Concerning other materials
please consult the worktop manufac-
turer.
If the remote fan unit is installed within
the bottom cabinet and if combined
with VK or VF ensure accessibility to
the outlets.
The remaining surface of the worktop
(min. 50 mm) between the cut-outs
must be reinforced with a support. It is
recommended to use furniture support
AA 409 400/430.
Ovens that do not exceed the maximum
allowed cabinet temperature can be
combined with the table ventilation if
built-in situation permits.
Recommendation for stainless steel
parts to match hood that have to be
welded and polished: brushed
grain 280.
Surfaces: Stainless steel 1.4301,
ground and brushed IIIC.
For air recirculation:
The exhaust outlet in the plinth should
be as large as possible to minimise
draughts.
The location of the exhaust outlet in the
plinth is consumer-defined. Minimum
cross-section 720 cm².
To avoid smoke when frying/grilling
refer to the manuals of VR/VP.
The exhaust outlet in the plinth should
be as large as possible to minimise
draughts.
The location of the exhaust outlet in the
plinth is consumer-defined. Minimum
cross-section 720 cm².
To avoid smoke when frying/grilling
refer to the manuals of VR/VP.
For air extraction:
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
Duct connection front or backwards:
2 ducts DN 150 cylindrical or flat
rectangular duct. Downwards 2 ducts
DN 150 flat rectangular duct
(installation accessory).
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
Duct connection front or backwards:
2 ducts DN 150 cylindrical or flat
rectangular duct. Downwards 2 ducts
DN 150 flat rectangular duct
(installation accessory).
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
Connection
Connecting cable 1.7 m with plug.