Gaggenau AL400721 Brochure

Page of 356
202
Ventilation appliances
    
   A   T 400 101
 
   Stainless  steel
  Width  106  cm
  Air  extraction/recirculation
     A   T 400 131
 
   Stainless  steel
  Width  136  cm
  Air  extraction/recirculation
          Installation  accessories
    A   A 010 410
 
  Air exhaust grille recirculation mode
   Stainless  steel  coloured,  90  cm, 
including installation fittings, height 
adjustable.
     A   A 409 400
 
  Furniture support 86 cm for table 
ventilation 106/90 cm
   Recommended as bearer for the 
worktop, instead of a cabinet frame.
     A   A 409 430
 
  Furniture support 116 cm for table 
ventilation 136/120 cm
   Recommended as bearer for the 
worktop, instead of a cabinet frame.
     A   A 409 900
 
  Telescopic extension 110 mm for 
AT 400 101
      A   A 409 930
 
  Telescopic extension 110 mm for 
AT 400 131
      Z   B 020 090
 
  Ventilation grille stainless steel
   Extension piece for 30 mm, necessary 
for height adjustment.
  Order 1 for height adjustment of 
31-60 mm.
Order 2 for height adjustment of 
61-70 mm.
       Special  accessories
    A   A 400 010
 
  Beech cutting board, 28 cm deep, fits 
the workspace on top of the AT 400
      A   A 400 200
 
  Glass cover, matt-finished, 106 cm, 
thickness 6 mm, with spacer
      A   A 400 230
 
  Glass cover, matt-finished, NO_FEA-
TURE, thickness 6 mm, with spacer
      A   A 409 101
 
  Activated charcoal air filter incl. 2 extra 
fine grease filters for AT 400 101
      A   A 409 131
 
  Activated charcoal air filter incl. 2 extra 
fine grease filters for AT 400 131
        Installation  accessories  for  the  air 
recirculation ducts you will find at the 
pages     236–239 .
    
 
 
   Table  ventilation
  A   T 400 
 
–    An eye-catcher for an island 
solution or with CI 490 for the 
60 cm deep worktop
 
–   Highly effective air recirculation 
technology, 750 m³/h air output at 
source
 
–   Additional  workspace
 
–   Minimal planning and easy 
installation for air recirculation
     Output
  Performance output level 3/Intensive:
Air output according to DIN EN 61591.
Sound power and sound pressure 
depending on built-in situation.
  Appliance width 106/136 cm
 Air  extraction:
660 / 750 m³/h.
  Air  recirculation:
680 / 750 m³/h.    
     Features
  3 electronically controlled output 
levels.
  Intensive  mode.
  Interval  ventilation.
  Run-on  function.
  Grease filter saturation indicator.
  Centrifugal grease filter and drip trays, 
dishwasher-safe.
  Fluorescent  tube   30/36   W .
  Order activated charcoal filter mat 
separately.
    Planning  notes
  AT 400 101 for operation with 2 Vario 
400 series cooktops or cooktops up to 
92 cm  wide.
AT 400 131 for operation with 3 Vario 
400 series cooktops or cooktops up to 
122 cm  wide.
For operation with 3 Vario 200 series 
cooktops, 2 Vario 400 Series cooktops 
or a cooktop configuration of up to 
92 cm  wide.
  Max. output of glass ceramic cooktops 
12 kW.
  In combination with the cooktop 
CI 490, installation in 60 cm deep 
worktops is possible.
  Operation in combination with gas 
cooktops is not permitted.
  The remaining surface of the worktop 
(min. 50 mm) between the cut-outs 
must be reinforced with a support. It is 
recommended to use furniture support 
AA 409 400/430.
  Intermediate shelves in the lower 
cabinet must be removable.
  Hinges on swing doors may have to be 
repositioned.
  The connecting cables of the cooking 
appliances are laid through the middle 
of the air duct to the rear.
  Water inlet and outlet pipes must not 
be laid through the air duct.
  When operating Vario cooktops, the 
appliance cover needs to be removed.
  Ovens that do not exceed the maximum 
allowed cabinet temperature can be 
combined with the table ventilation if 
built-in situation permits.
  The table ventilation cover must remain 
removable to permit changing of the 
lamp.
  Recommendation for stainless steel 
parts to match hood that have to be 
welded and polished: brushed 
grain 280.
  Surfaces: Stainless steel 1.4301, 
ground and brushed IIIC.
  For  air  recirculation:
  Order activated charcoal filter mat 
separately.
  The opening in the lower cabinet shelf 
may be increased as long as a 
minimum cross-section of 1,800 cm² is 
maintained.
  The exhaust outlet in the plinth should 
be as large as possible to minimise 
draughts.
  The location of the exhaust outlet in the 
plinth is consumer-defined. Minimum 
cross-section 720 cm².
  To avoid smoke when frying/grilling 
refer to the manuals of VR/VP.
  For  air  extraction:
  Attachment of exhaust pipe directly in 
the blower housing using flexible duct 
DN 150 or 90° elbow pipe AD 752 030. 
Break-out openings for cylindrical pipe 
AD 752 010 in the blower housing.
  For maximum duct lengths use 
Gaggenau flat rectangular ducts AD 8… 
or Naber-System Compair flow. Other 
flat ducts are not permitted!
  When installing a ventilation hood with 
air extraction mode and a chimney-
vented fireplace, the hood's power 
supply line needs a suitable safety 
switch.
   
     Connection
  Total  connected  load   310/316   W .
  Connecting cable 2.0 m with plug (from 
middle of appliance).