Ventilation appliances
219
A H 900 161
Stainless steel front panel
Width 60 cm
Air extraction/recirculation
Width 60 cm
Air extraction/recirculation
A H 900 171
Stainless steel front panel
Width 70 cm
Air extraction/recirculation
Width 70 cm
Air extraction/recirculation
A H 900 191
Stainless steel front panel
Width 90 cm
Air extraction/recirculation
Width 90 cm
Air extraction/recirculation
Installation accessories
L L 010 000
L L 010 000
Air baffle
Fitted on upper cabinet above blow-out
opening, recirculating air. This
accessory prevents soiling of the
ceiling. For AH 900/250, AF 280.
Fitted on upper cabinet above blow-out
opening, recirculating air. This
accessory prevents soiling of the
ceiling. For AH 900/250, AF 280.
Special accessories
F F 900 056
F F 900 056
Metal grease filter for retrofitting
AH 900 161/171
AH 900 161/171
F F 900 091
Metal grease filter for retrofitting
AH 900 191
AH 900 191
K F 900 055
Activated charcoal air filter for
retrofitting AH 900 161/171
retrofitting AH 900 161/171
K F 900 090
Activated charcoal air filter for
retrofitting AH 900 191
retrofitting AH 900 191
Installation accessories for the air
recirculation ducts you will find at the
pages 236–239 .
recirculation ducts you will find at the
pages 236–239 .
Flat kitchen hood
A H 900
– From the inventor of flat kitchen
hoods
– Especially quiet
– Easy filter change
– Air extraction or recirculation
system
Output
Performance and noise level, output
level 3/Intensive:
Air output according to DIN EN 61591.
Sound power level according to
EN 60704-3.
Sound pressure level according to
EN 60704-2-13.
level 3/Intensive:
Air output according to DIN EN 61591.
Sound power level according to
EN 60704-3.
Sound pressure level according to
EN 60704-2-13.
Appliance width 60 cm
Air extraction:
440 / 600 m³/h.
54 / 61 dB (A) re 1 pW.
40 / 47 dB (A) re 20 μPa.
Air recirculation:
280 / 370 m³/h.
64 / 70 dB (A) re 1 pW.
50 / 56 dB (A) re 20 μPa.
440 / 600 m³/h.
54 / 61 dB (A) re 1 pW.
40 / 47 dB (A) re 20 μPa.
Air recirculation:
280 / 370 m³/h.
64 / 70 dB (A) re 1 pW.
50 / 56 dB (A) re 20 μPa.
Appliance width 70 cm
Air extraction:
440 / 600 m³/h.
54 / 61 dB (A) re 1 pW.
40 / 47 dB (A) re 20 μPa.
Air recirculation:
280 / 370 m³/h.
64 / 70 dB (A) re 1 pW.
50 / 56 dB (A) re 20 μPa.
Air extraction:
440 / 600 m³/h.
54 / 61 dB (A) re 1 pW.
40 / 47 dB (A) re 20 μPa.
Air recirculation:
280 / 370 m³/h.
64 / 70 dB (A) re 1 pW.
50 / 56 dB (A) re 20 μPa.
Appliance width 90 cm
Air extraction:
440 / 600 m³/h.
54 / 62 dB (A) re 1 pW.
40 / 47 dB (A) re 20 μPa.
Air recirculation:
280 / 370 m³/h.
64 / 71 dB (A) re 1 pW.
50 / 57 dB (A) re 20 μPa.
Air extraction:
440 / 600 m³/h.
54 / 62 dB (A) re 1 pW.
40 / 47 dB (A) re 20 μPa.
Air recirculation:
280 / 370 m³/h.
64 / 71 dB (A) re 1 pW.
50 / 57 dB (A) re 20 μPa.
Features
Controls at front.
3 electronically controlled output
levels.
Intensive mode.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Cartridge-type filter, dishwasher-safe.
Compact fluorescent lamp
1 x 36/1 x 36/2 x 24 W .
Light can be switched on separately.
Extendable steam screen 175 mm.
DN 150 exhaust air pipe.
3 electronically controlled output
levels.
Intensive mode.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Cartridge-type filter, dishwasher-safe.
Compact fluorescent lamp
1 x 36/1 x 36/2 x 24 W .
Light can be switched on separately.
Extendable steam screen 175 mm.
DN 150 exhaust air pipe.
Planning notes
For calculating the exhaust air line go
to Rodun online at
www.gaggenau.com.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
Vario cooktops with intensive
production of vapours like VR/VP/VF
should be placed in the middle
beneath the cooker hood (in this case
air recirculation is not recommended).
to Rodun online at
www.gaggenau.com.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
Vario cooktops with intensive
production of vapours like VR/VP/VF
should be placed in the middle
beneath the cooker hood (in this case
air recirculation is not recommended).
Clearance above gas appliances min.
60 cm (more than total load gas 12 kW
min. 70 cm).
Clearance above electric appliances
min. 47 cm.
To be installed in an upper cabinet
without base.
70 cm hood can be installed in 60 cm
upper cabinet.
To change the filter, the door of the
cabinet must be opened completely.
60 cm (more than total load gas 12 kW
min. 70 cm).
Clearance above electric appliances
min. 47 cm.
To be installed in an upper cabinet
without base.
70 cm hood can be installed in 60 cm
upper cabinet.
To change the filter, the door of the
cabinet must be opened completely.
Connection
Total connected load 230/230/240 W .
Connecting cable 1.5 m with plug.
Connecting cable 1.5 m with plug.