Gaggenau AL400721 Brochure

Page of 356
248
Ventilation appliances
Wall-mounted hoods.
Appliance type
Wall hood
Wall hood
Wall hood
Stainless steel
AW 210 190
AW 210 170
AW 220 120
Aluminium-lacquered
AW 211 190
AW 221 120
Stainless steel, motorless
Aluminium-lacquered, motorless
Air extraction / recirculation
•/•
•/•
•/•
Dimensions with ventilation duct
Width
(cm) 90
70
120
Depth
(cm) 48
48
50
Height, air extraction / recirculation, min. – max.
(cm) 65 – 142/76 – 142
65 – 142/76 – 142
65 – 141/65 – 152
Net weight, min. – max.
(kg) 19
16
27 – 29
Air extraction duct weight, min. – max.
(kg) 7 – 11
7 – 11
4 – 10
Air extraction performance (EN 61591), min / max / Int
Air extraction
(m³/h) 250/450/650
250/450/650
310/510/720
Air extraction Coanda eff ect 
(m³/h)
Air recirculation
(m³/h) 190/340/430
190/340/430
230/380/440
Air extraction Coanda eff ect 
(m³/h)
Max. back pressure at 0 m³/h
(Pa) 380
380
470
Sound power level (EN 60704-3) max / Int
Extraction mode
(dB(A) re 1 pW) 57/65
57/65
58/64
Recirculation mode
(dB(A) re 1 pW) 66/71
66/71
68/71
Sound pressure level (EN 60704-2-13) max / Int
Extraction mode
(dB (A) re 20 μPa) 43/51
43/51
44/50
Recirculation mode
(dB (A) re 20 μPa) 52/57
52/57
54/57
Air extraction performance (unobstructed) with fan units, min / max / Int
AR 400 131 for inside installation, intake DN 150
(m³/h)
AR 400 140 for inside installation, intake DN 150
(m³/h)
AR 401 131 for outside installation, intake DN 150
(m³/h)
AR 401 140 for outside installation, intake DN 150
(m³/h)
Features
Coanda eff ect
Glass cover
Rim extraction / rim extraction fi lters
•/•
Stainless steel grease fi lter
Fan output levels
(No.) 3
3
3
Intensive mode
Run-on function
Interval ventilation
Grease fi lter saturation indicator
Function indicators
Halogen lighting
(W) 3 x 20
3 x 20
4 x 20
Compact fl uorescent tube lighting
Illuminance
(lx) 400
480
520
Soft-Light
Exhaust air connection piece
(ø mm) 150
150
150
Exhaust air connection piece, top / side / rear  /front S = specially produced
•/S/•/S
•/S/•/S
•/S/•/S
Fans
(No.) 1
1
1
Fan output
(W) 160
160
215
Connecting cable length
(m) 1.3
1.3
1.3
Minimum clearance above cooking area
For gas appliances with total connected load gas of less / more than 12 kW
(cm) 65/70
65/70
65/70
For electric appliances
(cm) 60
60
55
Connection
Total connected load
(W) 220
220
295
Radio frequency interference-suppressed
• Standard.    – Not available.
¹ If the air output is high during the air circulation mode, a considerable drop in output and clearly increased noise in comparison with air extraction is to be expected. 
² The Coanda eff ect allows for operation at lower output levels.