252
Ventilation appliances
 Remote fan units.
Version
Outside wall
Outside wall
Stainless steel
AR 401 140
AR 401 131
Metal zinc plated
Air extraction / recirculation
•/–
•/–
Installation possibility
Slanted roof (not Eternit)
AA 401 910¹
AA 401 910¹
Outside wall
Inside wall
Bottom cupboard
Attic
Cellar
Dimensions
Width 
(mm) 366
366
Depth
(mm) 257
257
Height 
(mm) 460
460
Net weight
(kg) 15
13
Air extraction performance (EN 61591), Levels 1 / 2 / 3 / 4³
DN 200
DN 200
Air extraction
(m³/h) 400/550/860/1,100
310/450/590/850
Recirculation
(m³/h)
Max. back pressure at 0 m³/h
(Pa) 605
505
Features
Exhaust air intake connection piece
(ø mm) 200
200
Exhaust air outlet connection piece
(ø mm) –
Fans
(No.) 1
1
Fan output
(W) 520
355
Connecting cable length
(m) 1
1
Additional connector pair for extension
Ratings in combination with extraction element
Radio frequency interference-suppressed
• Standard.    – Not available.
¹ Special accessory.
² Depending on ventilation appliance levels are used 1–4 or as 1/2/3/Intensive.
³ Not known / confi rmed before going to print.