Installation instructions 
 
  In Canada: 
  Wiring must conform to Cana dian Electrical 
Code C22.1- latest edition. You can obtain a 
copy  of  the  Canadian  Electrical  Code  by 
writing  to:  Canadian  Standards  Association 
178  Rexdale  Boulevard  Rexdale  (Toronto), 
Ontario, Canada M9W 1R3 
4. Wire  size  (Copper  or  Aluminum  wire)  and 
connections must be suitable for the rating of 
the  appliance  as  per  the  National  Electrical 
Code  requirements.  The  flexible  armoured 
cable  extending  from  the  oven  should  be 
connected directly to the junction box. 
5. The  junction box should  be located so as to 
allow as much slack as possible between the 
junction  box  and  the  oven  so  it  can  be 
moved if servicing is ever required. 
6. A  U.L.  listed  conduit  connector  must  be 
provided  at  each  end  of  the  power  supply 
cable. 
Electrical connections 
Be  sure  your  appliance  is  properly  installed 
and  grounded  by  a  qualified  technician.  Ask 
your  dealer  to  recommend  a  qualified 
technician or an authorized repair service. 
This  appliance  is  manufactured  with  a  green 
GROUND  wire  connected  to  the  oven  chassis. 
After making sure that the power has been turned 
off,  connect  the  flexible  conduit  from  the  oven  to 
the  junction  box  using  a  U.L.  listed  conduit 
connector.  The  figures  and  the  instructions 
provided below present the most common way of 
connecting the ovens. 
Your  local  codes  and ordinances,  of  course,  take 
precedence over these instructions. 
WARNING”  Risk  of  Electric  Shock,  frame 
grounded  to  neutral  of  appliance  through  a 
link. 
Grounding  through  the  neutral  conductor  is 
prohibited  for  new  branch-circuit  installations 
(1996  NEC);  mobile  homes;  and  recreational 
vehicles,  or in an area where local codes prohibit 
grounding  through  the  neutral  conductor.  For 
installations  where  grounding  through  the  neutral 
conductor is prohibited: 
  Disconnect  the  ground  from  the  neutral  at 
free end of conduit; 
  Use  grounding  terminal  or  lead  to  ground 
unit; and 
  Connect  neutral  terminal  or  lead  to  branch 
circuit neutral in usual manner. 
3-Wire branch circuit (for US only) 
Refer  to  the  following  Figure,  where  local  codes 
allow  the  connection  of  GROUND  wire  from  the 
oven to the branch circuit NEUTRAL wire (gray or 
white colored wire): 
  If  local  codes  permit,  connect  the  green 
GROUND  wire  from  the  oven and the  white 
wire  from  the  oven  to  the  branch  circuit 
NEUTRAL wire (gray or white colored wire). 
  Connect  the  red  and  black  leads  from  the 
oven  to  the  corresponding  leads  in  the 
junction box.