Lynx L2500 Catalog

Page of 15
sPeCifiCaTions & insTallaTion
THe sedona by lynx ColleCTion
bUilt-in Grill
Model  
   A  
   b  
   c
L400 
23.00 10.00 21.25
L500  
29.00  
10.00 
21.25
L600 
35.00 10.00 21.25
coMPleMentArY ProDUcts
Model  
   A  
   b  
   c
LSB501
*
  
11.00 
4.00  
16.00
LSB502
*
  
21.00  
4.00  
16.00
LDR424 
22.00 19.00 –
LDR530  
28.25 
19.00  
–  
LDR636 
33.75 19.00 –
LSA530  
28.25  
19.00  
20.00
LSA636    
33.75 
19.00 
20.00
LUD517  
17.25  
12.75  
20.00 
L500REF  
21.50  
34.00 
24.50
Measurements in inches.
bUilt-in Grill With insUlAtinG JAcKet
Model  
   A  
   b  
   c
LIJ400 
30.00 11.62 23.25
LIJ500  
36.00  
11.62  
23.25
LIJ600 
42.00 11.62 23.25
1
1/8
” min. for model LUDE
3
1/2
” min. for model LUDXL
2
1/2
” min. for model LDR 
(access door)
  * Cocktail Pro should have an open bottom for plumbing and drain access.
** 1” square hole must be located at rear of  grill cutout. 120V GFI outlet must
    be located within 6’ of the 1” hole.
GAS
NON-COMBUSTIBLE 
CONSTRUCTION
3”
F
21 
3/4
'' 
2”Ø or 2” square holes
for manifold connection
(rear or bottom access)
12” min.
Grill**
Cocktail Pro*
Warming Drawer/
Convenience Center
Utility 
Drawer
Side
Burner
Access
Doors
19”
A
B
D
E
G
H
29”
2
1/4
” 
3
1/2
3
1/4
” min.
2”
H
3” min.
C
24”
Trash 
Center
36
3/8
min.
3
1/2
8
1/4
6
1/4
Trash 
Chute
5/8
'' 
3/16
'' 
 
              Single
Storage Drawer
16”
3”
min.
 
 
 
14
1/2
''
1/4
'' 
Towel
Dispenser
non-coMbUstible 
constrUction
The guides, measurements and dimensions detailed below are designated to assist you with planning your outdoor kitchen. 
note: Due to continuing product innovation, specifications are subject to change without notice.
iMPortAnt: Please reference the Care & Use / Installation manual for details on gas plumbing requirements, electrical specifications and the 
proper installation of your Lynx outdoor kitchen equipment. This manual can be downloaded from the Lynx website at www.lynxgrills.com
COUNTER TOP NOTCH DETAIL
Only required if island counter top overhangs the face of the island
Insulating 
Jacket
A
4.5”
5”
3”
note: Insulating jacket required for all grills installed into   
 
a combustible enclosure.
note: For natural Gas grills, Lynx recommends using 3/4” gas lines.
note: Side burners may be rotated 90 degrees.   
 
See installation manuals for details.
C
B
A
A
Double
Drawers
(LUD)
Single
& Double
Side Burner
(LSB)
Outdoor
Refrigerator
(L500REF)
CUTOUT NOT
REQUIRED
WITH LIJs
Door & Drawer Options
(LDR, LSA)
1.50” min.
C
B
B
A
A
3.50”
3.50”
12.00”
2.00”
34.00”
2.25”
21.50”
0.56”
When installing the LSB side burners 
over the refrigerator; the counter top 
must be at least 37-1/2” above the floor.