GE GTD42GASJ-WW Specification Sheet

Page of 4
Specification Revised 10/15
GTD42GASJ 
GE
®
 Series 7.2 Cu. Ft. Capacity Gas Dryer
For answers to your Monogram, GE Profile
™ 
Series  
or GE
®
 Series appliance questions, visit our website  
at geappliances.com or call GE Answer Center
®
  
service, 800.626.2000.
Exhaust OptiOn: When viewed from the front of the 
unit, exhaust 3-way via rear, left and bottom. Dryer is shipped 
exhausted to the rear. Alternate exhausting knockouts  
are supplied.
Gas:  An individual, properly-grounded branch circuit, with  
a three-prong grounding-type receptacle, protected by a 15  
or 20 amp circuit breaker or a time-delay fuse is required.
Gas DryEr ElEctric ratinG: 120V, 60Hz, 6A
Gas (Btu/hr): 22,000. Factory-equipped for natural gas. 
Tested for LP gas. LP gas supply requires a conversion kit. 
Check installation instructions for correct kit and have a 
qualified gas technician install a conversion kit. See dryer 
ducting information for proper installation.
nOtE: Dryer wall outlet must be located within 36" of service 
cord entry and accessible when dryer is mounted in position.
installatiOn infOrmatiOn: For complete information, 
see installation instructions packed with your dryer.
DimEnsiOns anD installatiOn infOrmatiOn (in inchEs)
spEcial installatiOn rEquirEmEnts
alcOvE Or clOsEt installatiOn: 
-  If your dryer is approved for installation in an alcove or closet, it will be stated  
on a label on the dryer back.
-  The dryer MUST be exhausted to the outside.
-   Minimum clearances between dryer cabinet and adjacent walls or other  
surfaces are: 0" either side; 3" front and rear.
-  Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
-   Closet doors must be louvered or otherwise ventilated and must contain a 
minimum of 60 sq. in. of open area equally distributed. If this closet contains  
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of  
open area equally distributed.
-  No other fuel-burning appliance shall be installed in the same closet  
with a gas dryer.
BathrOOm Or BEDrOOm installatiOn:
-  The dryer MUST be exhausted to the outdoors.
-   The installation must conform with the local codes, or in the absence  
of local codes, with the National Electric Code and National Fuel Gas  
Code, ANSI Z223 for gas dryers.
minimum clEarancEs OthEr than alcOvE Or clOsEt 
installatiOn:
-   Minimum clearances to combustible surfaces are: 0" both sides; 3" rear.
DryEr ExhaustinG infOrmatiOn : Use metal duct only, vertical  
and horizontal ducting.