Amana NED4705EW-WW Specification Guide

Page of 2
Electric Dryer
PRODUCT MODEL NUMBERS
Installation spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.
 
Additional spacing should be considered for ease of installation and servicing.
 
Additional clearances might be required for wall, door, and floor moldings.
 
Additional spacing of 1" (25 mm) on all sides of the dryer  
is recommended to reduce noise transfer.
 
For closet installation, with a door, minimum ventilation openings in the top and 
bottom of the door are required. Louvered doors with equivalent ventilation 
opening are acceptable.
 
Companion appliance spacing should also be considered.
W10514172A
02/2015
NED4600Y, NED4700Y, NED4655E, NED4705E
Installation clearances:
The location must be large enough to allow the dryer door to 
open fully.
 
Dryer Dimensions
*Most installations require a minimum 5½" (140 mm) clearance   
 behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”
Minimum Required Spacing
 
A
B
C
    18"*
(457 mm)
  1"
(25 mm)
29"
(737 mm)
        1"
   (25 mm)
        1"*
    (25 mm)
14" max.*
(356  mm)
   
27
¾"
(705 mm)
  48 in.
  
(310 cm )
2
*
2
       3"*
(76 mm)
       3"*
(76 mm)
  
24 in.
(155 cm )
*
2
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Additional spacing recommended
Minimum spacing for recessed area or closet installation