GE JB630RFSS Installation Guide

Page of 2
9
LEVEL THE RANGE
WARNING:
Never completely remove the leveling leg 
as the range will not be secured to the anti-tip device properly.
MODELS WITH STORAGE DRAWER OR KICK PANELS
A
   Plug in unit and slide into place. Pull drawer out until it stops. 
B
   Lift front of drawer until the stops clear the guide. Remove the drawer.
C
   Install the oven shelves in the oven and position the range where 
it will be installed.
D
   Check for levelness by placing a spirit level on one of the oven shelves. 
Take two readings—with the level placed diagonally first  
in one direction and then the other.
E
   The front leveling legs can be adjusted from the bottom 
and the rear legs can be adjusted from the top or the bottom.
F
   Use an adjustable wrench to adjust the leveling legs until 
the range is level.
BEFORE YOU BEGIN
Read these instructions completely and  
carefully.
IMPORTANT — 
Save these instructions 
for local inspector’s use.
IMPORTANT —
 
Observe all 
governing codes and ordinances.
•   Note to Installer – Be sure to leave these 
instructions with consumer.
•   Note to consumer – Keep these  
instructions for future reference.
•   Skill level – Installation of this appliance 
requires a qualified installer or electrician.
•   Proper installation is the responsibility of the 
installer. 
•   Product failure due to improper installation is 
not covered under warranty.
FOR YOUR SAFETY:
If you did not receive an anti-tip bracket with your purchase,  
call 1.800.626.8774 to receive one at no cost. (In Canada,  
call 1.800.561.3344.) For installation instructions of the bracket,  
visit: www.GEAppliances.com. (In Canada, www.GEAppliances.ca.)
Installation Instructions
Free-Standing Electric Ranges
MATERIALS YOU MAY NEED
TOOLS YOU WILL NEED
(UL Listed 40 AMP)  
4-Wire Cord 4’ long OR  
3-Wire Cord 4’ long
Squeeze Connector  
(For Conduit 
Installations Only)
1
REMOVE PACKAGING MATERIALS: 
Failure to remove packaging materials could 
result in damage to the appliance. Remove all packing parts from oven, racks, heating elements 
and drawer. Also, remove protective film and labels on the outer door, cooktop and control panel. 
Drill with 1/8” Bit
Safety Glasses
Adjustable Wrench
Level
Tin Snips
Tape Measure
Pliers
1/4” Nut Driver
•  A child or adult can tip the range and be killed.
•  Install the anti-tip bracket to the wall or floor.
•  Engage the range to the anti-tip bracket by sliding the 
  range back such that the foot is engaged.
•  Re-engage the anti-tip bracket if the range is moved.
•  Failure to do so can result in death or serious burns
  to children or adults.
Tip-Over Hazard
WARNING
Questions?
Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
WARNING —
 
Before beginning 
the installation, switch power off at service 
panel and lock the service disconnecting 
means to prevent power from being 
switched on accidentally. When the service 
disconnecting means cannot be locked, 
securely fasten a prominent warning device, 
such as a tag, to the service panel.
2
PREPARE THE OPENING (FOR INDOOR USE ONLY)
See illustrations for all rough-in and spacing dimensions. The range may be placed with 0” 
clearance (flush) at the back wall and side walls of the cabinet.
2
1
2
2
1
2
7
1
2
25”
47”
25
3
8
7”
14
1
2
On models with baking 
or warming drawers, 
electrical outlet must not 
be in this area.
3
1
4
3
1
4
7
3
4
23
1
2
47”
29
7
8
25
3
8
45”
36”
SINGLE OVEN
DOUBLE OVEN
A
NOTE C
B
A
C
Both 
Sides
NOTE: Use a 4’ power cord to prevent interference 
with the storage drawer. Power cords 4
1
2
’ to 6’ long 
may have to be dressed to allow for proper drawer 
closing.
MINIMUM DIMENSIONS BETWEEN COOKTOP,
WALLS AND ABOVE THE COOKTOP:
A.
 Make sure the wall covering, countertop, flooring 
and cabinets around the range can withstand the 
heat (up to 200°F) generated by the range.
B.  Allow 30” minimum clearance between surface 
units and bottom of unprotected wood or metal 
cabinet, or allow a 24” minimum when bottom  
of wood or metal cabinet is protected by no less 
than 1/4” thick flame retardant millboard covered 
with not less than No 28 MSG sheet metal, (.015”), 
.015” thick stainless steel, .024”  
aluminum or .020” copper.
Acceptable electrical outlet area. 
Orient electrical receptacle so the 
length is parallel to floor.
*  GE-branded models have control 
panels 30
7
8
” wide.
30”
47
5
8
30”
C.  This appliance has been approved for 0” spacing to adjacent surfaces above the cooktop. However, 
a 6” minimum spacing to surfaces less than 15” above the cooktop and adjacent  
cabinet is recommended to reduce exposure to steam, grease splatter and heat.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space 
above the cooktop should be avoided. If cabinet storage space is to be provided above  
the cooktop, the risk can be reduced by installing a range hood that projects at least 5” beyond  
the front of the cabinets. Cabinets installed above the cooktop must be no deeper than 13”.
29
7
8
*
*
3
ELECTRICAL REQUIREMENTS
WARNING:
This appliance must be properly grounded.
WARNING:
All new constructions, mobile homes, recreational vehicles and installations where 
local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord.
WARNING:
To prevent fire or shock, do not use an extension cord with this appliance. 
WARNING:
To prevent shock, remove house fuse or open circuit breaker before 
beginning installation.
We recommend you have the electrical wiring and hookup of your range connected by a qualified 
electrician. After installation, have the electrician show you how to disconnect power from the range.
You must use a single-phase, 120/208 VAC or 120/240 VAC, 60 hertz electrical system. If you connect 
to aluminum wiring, properly installed connectors approved for use with aluminum wiring must be 
used.
Effective January 1, 1996, the National Electrical Code requires that new construction (not 
existing) utilize a 4-conductor connection to an electric range. When installing an electric range 
in new construction, mobile home, recreational vehicle, or an area where local codes prohibit 
grounding through the neutral conductor, refer to the section on four-conductor branch circuit 
connections.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven 
according to governing codes could result in a hazardous condition. If there are no local codes, your 
oven must be wired and fused to meet the National Electrical Code, NFPA No. 
70 – latest edition, available from the National Fire Protection Association.
This appliance must be supplied with the proper voltage and frequency, and connected to an 
individual, properly grounded, 40 amp (minimum) branch circuit protected by a circuit breaker 
or time-delay fuse.
Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with ring 
terminals on wire and a strain relief device.
A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord 
is not recommended but if used, it should be marked for use with nominal 1
3
8
” diameter connection 
openings. Care should be taken to center the cable and strain relief within the 
knockout hole to keep the edge from damaging the cable.
The rating plate is located on the oven frame or on the side of the drawer frame.
Rating plate
SINGLE OVEN
Rating plate
DOUBLE OVEN
4
POWER CORD AND CONDUIT INSTALLATION
A
   Remove wire cover (on the back of range) by removing screws using a 1/4” nut driver. You can 
access the terminal block by either removing a terminal block cover (on some models) or the 
wire cover. Do not discard these screws.
B
   For power cord and 1” conduit only, remove the 
knockout ring (1
3
8
”) located on bracket directly 
below the terminal block. To remove the 
knockout, use a pair of pliers to bend the 
knockout ring away from the bracket and  
twist until ring is removed.
D
   For 3/4” conduit installations only, purchase a squeeze connector matching the diameter 
of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector  
and tighten. Allow enough slack to easily attach the wires to the terminal block. NOTE: Do not install the 
conduit without a squeeze connector. The squeeze connector MUST be installed before reinstalling 
the rear range wiring cover.
Wire cover
5 screws to 
remove wire 
cover
Retaining 
tabs
Back of range
Terminal block cover
Screw to 
remove  
terminal 
block cover
Back of range
Knockout 
ring in 
bracket
Knockout ring 
removed
Terminal block 
(appearance  
may vary)
C
   For power cord installations only 
(see the next step if using conduit), 
assemble the strain relief in the hole. Insert 
the power cord through the strain relief 
and tighten. Allow enough slack  
to easily attach the cord terminals to  
the terminal block. If tabs are present at 
the end of the winged strain relief, they 
can be removed for better fit.
 
 NOTE: Do not install the power cord without a 
strain relief. The strain relief bracket MUST be 
installed before  
reinstalling the rear range wiring cover.
Power cord
Strain relief
Terminal 
block
Bracket
Squeeze 
connector
Terminal block
Conduit
Bracket
Proceed to step 5 or 6.
Wire tips
Terminal  
block
Conduit
5
3-WIRE INSTALLATION
WARNING:
 
The neutral or ground wire of the power cord must be connected 
to the neutral terminal located in the center of the terminal block and the ground strap must connect the 
neutral terminal to the ground plate. The power leads must be connected to the lower left and the lower right 
terminals of the terminal block.
DO NOT remove the ground strap connection.
FOR POWER CORD INSTALLATION
A.
Remove the 3 lower terminal screws from the terminal block. 
B.  Insert the 3 terminal screws through each power cord terminal ring and into the lower 
terminals of the terminal block. Be certain that the center wire (white/neutral) 
is connected to the center lower position of the terminal block. 
C. Tighten screws securely into the terminal block.
FOR CONDUIT INSTALLATION
A.
 Loosen the 3 lower terminal screws on the terminal block. Strip wire to exposed tip about 5/8” long.
B.  Insert the center (white/neutral) wire tip through the bottom center terminal block opening. 
On certain models, the wire will need to be inserted through the ground strap opening  
and then into the bottom center block opening. Insert the two side bare wire tips into  
the lower left and the lower right terminal block openings. 
C.  Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten 
the screws.
NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated 
for the correct amperage and voltage. 
PROCEED TO STEP 7.
Ground strap
Terminal block  
(appearance 
may vary)
Neutral terminal
Power cord
Ground  
plate
Power Cord
Conduit
31-10816
08-11 GE
6
4-WIRE INSTALLATION
WARNING:
 
The neutral wire of the supply circuit must be connected to the neutral terminal 
located in the lower center of the terminal block. The power leads must be connected to the lower left and the 
lower right terminals of the terminal block. The grounding lead must be connected to the frame of the range with 
the ground plate and the green ground screw.
FOR POWER CORD INSTALLATION
A.
 Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground 
plate and retain them. Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS.
B.  Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate 
and into the frame of the range.
C.  Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower 
terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower 
position of the terminal block. Tighten screws securely into the terminal block.
FOR CONDUIT INSTALLATION
A.
  Loosen the 3 lower terminal screws on the terminal block. Remove the ground screw and ground plate and 
retain them. Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS. Strip wire to exposed tip 
about 5/8” long.
B.  Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) 
and secure it in place with the ground screw (removed earlier). Insert the bare wire (white/neutral) tip through 
the bottom center of the terminal block opening. Insert the two side bare wire tips into the lower left and the 
lower right terminal block openings. 
C.  Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws.
NOTE: ALUMINUM WIRING: Aluminum building wire may be used but it must be rated 
for the correct amperage and voltage. 
Before–Power Cord and Conduit
Terminal 
block
Terminal 
block
Neutral  
terminal
Neutral 
terminal
Ground 
strap
Ground plate 
(grounding to 
range)
Ground 
screw
Ground strap 
or
After–Conduit
Terminal 
block
Ground 
plate 
(grounding 
to range)
Wire 
tips
Ground screw
After–Power Cord
7
REPLACE THE WIRE COVER
Replace wire cover on range back by sliding its left edge under the retaining tabs and replace the 
screws removed earlier. Make sure that no wires are pinched between cover and range back.
Wire cover
5 screws to 
remove wire 
cover
Retaining 
tabs
Back of range
Terminal 
block cover
Screw to 
remove  
terminal 
block cover
Back of range
8
ANTI-TIP DEVICE INSTALLATION
To reduce the risk of tipping the range, the 
range must be secured by a properly installed 
anti-tip bracket. See installation instructions 
shipped with the bracket for complete details 
before attempting to install. 
To check if the bracket is installed and 
engaged properly, look underneath the range 
to see that the rear leveling leg is engaged 
in the bracket. On some models, the storage 
drawer or kick panel can be removed for 
easier inspection. If visual inspection is not 
possible, slide the range forward, confirm the anti-tip bracket is securely attached to the floor or wall, and 
slide the range back so the leveling leg is under the anti-tip bracket. If the range is pulled from the wall for 
any reason, always repeat this procedure to verify the range is properly secured by the anti-tip bracket. 
Never completely remove the leveling legs or the range will not be secured to the anti-tip bracket. 
•  A child or adult can tip the range and be killed.
•  Install the anti-tip bracket to the wall or floor.
•  Engage the range to the anti-tip bracket by sliding the 
  range back such that the foot is engaged.
•  Re-engage the anti-tip bracket if the range is moved.
•  Failure to do so can result in death or serious burns
  to children or adults.
Tip-Over Hazard
WARNING
Stop
10
  FINAL INSTALLATION CHECKLIST
•  Check to make sure the circuit breaker is closed (RESET) or the circuit fuses are replaced.
•  Be sure power is in service to the building.
•  Check that all packing materials and tape have been removed. This will include tape on metal panel under 
control knobs (if applicable), adhesive tape, wire ties, cardboard and protective plastic. Failure to remove 
these materials could result in damage to the appliance once the appliance has been turned on and 
surfaces have heated.
•  Check that the door and drawer are parallel to each other and that both operate smoothly. If they  
do not, see the Owner’s Manual for proper replacement.
•  Check to make sure that the rear leveling leg is fully inserted into the Anti-Tip bracket and that the bracket 
is securely installed.
OPERATION CHECKLIST
•  Turn on one of the surface units to observe that the element glows within 60 seconds. Turn the unit 
off when glow is detected. If the glow is not detected within the time limit, recheck the range wiring  
connections. If change is required, retest again. If no change is required, have building wiring checked for 
proper connections and voltage.
•  Check that the Clock (on models so equipped) display is energized. If a series of horizontal red  
lines appear in the display, disconnect power immediately. Recheck the range wiring connections.  
If change is made to connections, retest again. If no change is required, have building wiring checked for 
proper connections and voltage. It is recommended that the clock be changed if the red lines appear.
•  Be sure all range controls are in the OFF position before leaving the range.
9
LEVEL THE RANGE (CONT.)
G
   Position cord so that it does not interfere with drawer. 
Place drawer rail on guides. Push the drawer in until it stops.
H
   Lift front of drawer and push in until the stops clear 
the guides.
I
   Lower the front of the drawer and push in until it closes.
MODELS WITH BAKING, WARMING DRAWERS OR DOUBLE OVEN
A
   Plug in the unit.
B
   Measure the height of your countertop at the rear of the opening (X).
C
   Adjust two rear leveling legs so that the rear of cooktop is at the same height 
as the counter (Y).
D
  Slide unit into place.
E
   Install oven shelves in the oven and position the range where it will be installed.
F
   Check for levelness by placing a spirit level on one of the oven shelves. 
Take two readings—with the level placed diagonally first in one direction  
and then the other.
G
   Adjust front leveling legs until the range is level.
X
Y
3”
4”
Leg  
leveler
Lower  
range
Raise  
range
Spirit level
Anti-Tip Bracket 