Signature Series – HP15 Models
Model
Min Temp Set Max Temp Set
Factory Temp 
Setpoint
HP15R
30° F
42° F
38° F
HP15B
30° F
48° F
42° F
HP15W
40° F
68° F
45° F
HP15T
30° F
42° F
38° F
Signature Series – HP24 Models
Model
Min Temp Set Max Temp Set
Factory Temp 
Setpoint
HP24R
30° F
42° F
38° F
HP24F
-10° F
10° F
0° F
HP24B
30° F
48° F
42° F
HP24W
40° F
68° F
45° F
HP24T
30° F
42° F
38° F
Signature Series – HP48 Models
Model
Min Temp Set Max Temp Set
Factory Temp 
Setpoint
HP48FR
- 10° F
10° F
Freezer - 0° F
30° F
42° F
Refrigerator - 38° F
HP48RR
30° F
42° F
38° F
HP48RB
30° F
42° F
38° F
HP48RW
30° F
42° F
Refrigerator - 38° F
40° F
68° F
Wine Reserve - 55° F
HP48WO
40° F
68° F
45° F
HP48WW
40° F
68° F
45° F
 
LED Functions
The following table describes LED functions
LED
Mode
Function
ON
Compressor is on
Flashing
Anti-short cycle
delay is on
ON
Defrost is on
ON
Alarm is on
Flashing
You are in the process of 
programming the unit
 
DIAL TEMPERATURE CONTROL
C-Series, ADA-Compliant & Shallow-Depth Models
C
O
O
LE
R
OFF
1
2
3
4
5
6
COLD
Figure 2.  Dial Temperature Controller
Use a straight slot screwdriver to adjust the dial 
temperature control. The control is located at the top rear 
panel of the cabinet. Approximate temperature ranges are 
as follows:
C-Series Models
Model
Factory Temp Setpoint
HC24R
38° F
HC24BB
42° F
HC24WB
55° F
ADA-Compliant Series
Model
Factory Temp Setpoint
HA24RB
38° F
HA24FB
0° F
HA24BB
42° F
HA24WB
55° F
Shallow-Depth Series
Model
Factory Temp Setpoint
HH24RS
38° F
HH24BS
42° F
HH24WS
55° F
 
Adjust the temperature as follows:
Colder Temperature:
Turn the adjusting screw clockwise (to the right).
Warmer Temperature:
Turn the adjusting screw counterclockwise (to the left).
Temperature Control OFF:
Turn the adjusting screw completely counterclockwise to 
the OFF position until a click is heard.
NOTE: The condenser fan motor turns off with the compressor.