Le Cache European Country Euro 3800 458-Bottle Wine Cellar - Provincial Cherry Finish Owner's Manual

Page of 31
L E   C A C H E   P R E M I U M   W I N E   C A B I N E T S 
 
 
 
-22- 
 
HA2 The 
condenser 
temperature 
is too high 
(above 
125°F for 2 
hours) 
Check for appropriate installation, ventilation, ambient 
conditions and cooling capacity (Chapter II) 
Clean the condenser coils (see “Maintenance” in 
Chapter IV);  
Check for obstructions to the intake and/or exhaust 
vents; 
Check that the condenser fan is operating 
LA The 
temperature 
inside the 
cellar is too 
cold (below 
45°F) 
Raise the ambient temperature; Raise the “Minimum 
Set Point” 
LA2 The 
temperature 
at the 
condenser 
coils (outside 
the cabinet) 
has dropped 
below the 
alarm 
temperature 
setting 
Lower the alarm temperature setting as follows: 
1.  Depress the “Set” and “Down” button for three 
seconds until the display reads “HY” 
2.  Depress the “Set” and “Down” button for seven 
seconds until “PR2” flashes on the display 
3.  Using the “Down” button, scroll until the display 
reads “AL2” 
4.  Depress the “Set” button and lower the alarm 
temperature setting to your desired setting  
* Please note:  the temperature alarms (HA, HA2, LA and LA2) are disabled during the first 23 
hours of operation after the cooling unit is plugged in and/or turned on.