CONNECTING THE REGULATOR TO THE 
CO2 CYLINDER
1.  Remove the blue plug from the regulator fitting, but do 
not remove the carbonic washer.
2.  Screw regulator onto gas cylinder valve. Tighten with 
wrench until vertically straight. Be sure that the shut-off 
valve on the regulator is in the OFF (horizontal) position.
3.  Place screw clamp over the end of red line and push onto 
regulator tail piece. Tighten clamp with a screwdriver. 
4.  Turn regulator adjusting screw counterclockwise until 
it turns freely.
5.  Turn hand valve counter-clockwise on the CO2 cylinder 
to the fully open position.
6.  Turn regulator adjusting screw clockwise until desired 
pressure is reached (approximately 12-15 lbs.) Tighten 
stop nut on adjusting screw.
7.  Open shut-out valve on bottom of regulator.
CO2 LEAK TEST
Dilute a small amount of liquid dishwashing soap and rub 
the soapy mixture around each connection. If bubbles 
appear, tighten the connection.