Jenn-Air JGD3430W Leaflet

Page of 2
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to installation instructions
packaged with product before selecting cabinetry, making cutouts or beginning installation.
All Jenn-Air
®
appliances are appropriately UL, CUL or CSA approved.
®Registered trademark/™Trademark of Jenn-Air, U.S.A.
©2009. All rights reserved.
JGD3430W
PrODuCT DiMenSiOnS
C
B
A
C
A
B
D
E
F
G
H
I
A
B
C
D
E
F
G
H
I
K
L
M
M
N
K
J
C
B
A
C
A
B
D
E
F
G
H
I
A
B
C
D
E
F
G
H
I
K
L
M
M
N
K
J
A.  21
1
2
" (54.6 cm)
B.  19
11
16
" (50.0 cm)
C.   Model/serial rating  
plate location
 
A.  30" (76.2 cm)
B.  Combustible area above countertop (shown by dashed box)
C.   30" (76.2 cm) minimum clearance between top of cooktop platform and bottom  
of uncovered wood or metal cabinet (24" [61.0 cm] minimum clearance if bottom  
of wood or metal cabinet is covered by not less than 
1
4
" [0.6 cm] flame retardant millboard  
covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, or 0.024" 
[0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D.  13" (33.0 cm) recommended upper cabinet depth
E.  2
1
8
" (5.4 cm)
F.  19
15
16
" (50.6 cm) 
G.   18" (45.7 cm) minimum clearance from upper cabinet to countertop  
within minimum horizontal clearances to cooktop
H.  Junction box or outlet: 12" (30.5 cm) minimum from bottom of countertop 
I.   Junction box or outlet: 10" (25.4 cm) from right-hand side of cabinet
J.  28
5
8
" (72.7 cm)
K.   6" (15.2 cm) minimum distance to nearest left and right side combustible  
surface above cooktop
L.  1" (2.5 cm) minimum clearance between back wall and countertop
M.  Gas Line Opening – Wall: anywhere 6" (15.2 cm) below underside of countertop.  
Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is recommended.
N.  25" (63.5 cm) depth of countertop
Notes: After making the countertop cutout, some installations may require notching  
down the base cabinet side walls to clear the cooktop base. To avoid this modification,  
use a base cabinet with side walls wider than the cutout.
•  A minimum side clearance of 6" (15.2 cm) is recommended between side of cooktop  
and side wall for maximum ventilation performance.
•  A minimum clearance of 2" (5.1 cm) is recommended between the motor/blower and cabinet  
for proper cooling. A 6" (15.2 cm) clearance is recommended for servicing access.
B
C
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
J
I
B
C
D
E
F
G
H
A
L
I
K
J
A.  28
5
8
" (72.7 cm) maximum
B.  19
15
16
" (50.6 cm) maximum
C.  8
1
2
" (21.6 cm)
D.  5
3
4
" (14.6 cm) 
E.   2
1
8
" (5.4 cm) minimum space  
to front edge of cooktop
F.  Floor exhaust option
G.  6
1
8
" (15.6 cm) for 6" vent system
H.  8
1
2
" (21.6 cm)
I.  16" (40.6 cm) 
J.  Wall exhaust option
C
B
A
C
A
B
D
E
F
G
H
I
A
B
C
D
E
F
G
H
I
K
L
M
M
N
K
J
CuTOuT DiMenSiOnS
A.  30" (76.2 cm)
B.   12
15
16
" (32.9 cm) centerline 
of cooktop to centerline of 
gas manifold pipe
C.   4" (10.2 cm)
D.  6
19
32
" (16.8 cm)
E.  18
7
16
" (46.8 cm)
F.   1
11
16
" (4.3 cm) 
recommended minimum 
cabinet to motor clearance
G.  12
1
2
" (31.8 cm)
H.  14" (35.6 cm)
I.  28
1
4
" (71.8 cm)
1-800-jenn-air 
1-800-536-6247
jennair.com
08/09 29177RC