Sierra Wireless DART 300 User Manual

Page of 137
References 
 
DART 300 Modem 
 
Page 108 
 
2110212 Rev 1.0 
 
Table 12-4:  S-Registers in CDPD Mode (continued) 
Register Description 
Range 
Default 
Units 
TCP PAD Timeout 
This is a timer for the TCP connection (both originate and 
answer) and disconnection handshake operations. 
For originate connections this timer must also allow for 
network registration if the modem is not registered prior to the 
Dial command. 
For disconnects, if the timer expires prior to a graceful TCP 
disconnection, the modem will disconnect without completing 
the handshake. 
15 – 255 
60 
Seconds 
12 
Escape Guard Time 
This register determines the minimum idle period before and 
after the entry of the escape code sequence (+++ or as defined 
in S2).  Also, it defines the maximum period, in fiftieths of a 
second, allowed between consecutive asynchronous escape 
characters (S2) for the time dependent escape sequence to be 
considered valid. 
If this register is set to 0, the guard time of the escape 
sequence is disabled. 
0 – 255 
0.02s 
14 
Bit Mapped Options (Read Only) 
Bit 
Meaning 
 0 
(clear) 
 1 
(set) 
b0 reserved 
b1 Echo 
(E)  
On  
Off 
b2 Quiet 
(Q)  
Disabled Enabled 
b3 Verbose 
(V)  
Numeric 
 
Word 
b4 reserved 
b5 reserved 
b6 reserved 
b7 reserved 
Defaults shown in bold
 10 
(0x0A) 
 
21 
Bit Mapped Options  (Read Only) 
Bits 
b 0 
Setting of &I (Ring Indicator) (On
b 2,1 
reserved 
b 4,3 
00 
&D0 is selected (Ignore DTR) 
01 
&D1 is selected (go to cmnd state) 
10 
&D2 is selected (go to cmnd state off-line) 
11 reserved 
b 5,6,7  reserved. 
Defaults shown in bold
 17 
(0x11) 
 
30 
PAD Inactivity Timeout 
Specifies the amount of time after which a UDP or TCP PAD 
session / connection automatically terminates (hangs up) due 
to inactivity. 
0 
Disabled  (Default) 
1 – 20  Enabled timeout in minutes 
0 – 20 
00 
Minutes