Emerson MMI-20019043 User Manual

Page of 374
4.5.1
Configure Density Measurement Unit
Display
OFF-LINE MAINT
 > OFF-LINE CONFG > UNITS > DENS
ProLink II
ProLink
 > Configuration > Density > Density Units
ProLink III
Device Tools
 > Configuration > Process Measurement > Density
Field Communicator Configure > Manual Setup > Measurements > Density > Density Unit
Overview
Density Measurement Unit
 specifies the units of measure that will be displayed for density
measurement.
Procedure
Set Density Measurement Unit to the option you want to use.
The default setting for Density Measurement Unit is g/cm3 (grams per cubic centimeter).
Options for Density Measurement Unit
The transmitter provides a standard set of measurement units for Density Measurement Unit.
Different communications tools may use different labels.
Options for Density Measurement Unit
Table 4-10:   
Unit description
Label
Display
ProLink II
ProLink III
Field Communica-
tor
Specific gravity unit (not tem-
perature-corrected)
SGU
SGU
SGU
SGU
Grams per cubic centimeter
G/CM3
g/cm3
g/cm3
g/Cucm
Grams per liter
G/L
g/l
g/l
g/L
Grams per milliliter
G/mL
g/ml
g/ml
g/mL
Kilograms per liter
KG/L
kg/l
kg/l
kg/L
Kilograms per cubic meter
KG/M3
kg/m3
kg/m3
kg/Cum
Pounds per U.S. gallon
LB/GAL
lbs/Usgal
lbs/Usgal
lb/gal
Pounds per cubic foot
LB/CUF
lbs/ft3
lbs/ft3
lb/Cuft
Pounds per cubic inch
LB/CUI
lbs/in3
lbs/in3
lb/CuIn
API gravity
D API
degAPI
degAPI
degAPI
Short ton per cubic yard
ST/CUY
sT/yd3
sT/yd3
STon/Cuyd
Configure process measurement
46
Micro Motion
®
 Model 2700 Transmitters with Analog Outputs