Emerson MMI-20019043 User Manual
Option
Setup
A value written by
digital communica-
tions
digital communica-
tions
a. Choose Online > Configure > Manual Setup > Measurements > External
Pressure/Temperature
> Temperature.
b. Set External Temperature to Enabled.
c. Perform the necessary host programming and communications
c. Perform the necessary host programming and communications
setup to write temperature data to the transmitter at appropri-
ate intervals.
ate intervals.
Note
If the Weights & Measures application is implemented and the trans-
mitter is secured, digital communications cannot be used to write
temperature data to the transmitter.
mitter is secured, digital communications cannot be used to write
temperature data to the transmitter.
4.7.4
API reference tables
API reference tables, associated process fluids, and associated calculation values
Table 4-13:
Table
name
name
Process fluid
CTL source data
Reference temperature Density unit
5A
Generalized crude and
JP4
JP4
Observed density and
observed temperature
observed temperature
60 °F (non-configurable) Degrees API
Range: 0 to 100
5B
Generalized products
Observed density and
observed temperature
observed temperature
60 °F (non-configurable) Degrees API
Range: 0 to 85
5D
Lubricating oils
Observed density and
observed temperature
observed temperature
60 °F (non-configurable) Degrees API
Range:
−10 to +40
6C
Liquids with a constant
density base or known
thermal expansion coef-
ficient
density base or known
thermal expansion coef-
ficient
User-supplied reference
density (or thermal ex-
pansion coefficient) and
observed temperature
density (or thermal ex-
pansion coefficient) and
observed temperature
60 °F (non-configurable) Degrees API
23A
Generalized crude and
JP4
JP4
Observed density and
observed temperature
observed temperature
60 °F (non-configurable) Relative density
Range: 0.6110 to 1.0760
23B
Generalized products
Observed density and
observed temperature
observed temperature
60 °F (non-configurable) Relative density
Range: 0.6535 to 1.0760
23D
Lubricating oils
Observed density and
observed temperature
observed temperature
60 °F (non-configurable) Relative density
Range: 0.8520 to 1.1640
24C
Liquids with a constant
density base or known
thermal expansion coef-
ficient
density base or known
thermal expansion coef-
ficient
User-supplied reference
density (or thermal ex-
pansion coefficient) and
observed temperature
density (or thermal ex-
pansion coefficient) and
observed temperature
60 °F (non-configurable) Relative density
53A
Generalized crude and
JP4
JP4
Observed density and
observed temperature
observed temperature
15 °C (configurable)
Base density
Range: 610 to
1075 kg/m
Range: 610 to
1075 kg/m
3
Configure process measurement
Configuration and Use Manual
57