Sanyo XH3672R / CH3672R User Manual

Page of 180
IV-9
SM831148
4. Service procedures
1
2
3
4
5
6
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Replace outdoor unit 
control PCB.
(2)  [Alarm “P26”]
  
HIC PCB trouble)
IGBT short-circuit protection on inverter control (IPDU) PCB 
Is power OK?
 Correct power line.
Are
circuit wiring, 
connector
connections, and 
reactor
connections
OK?
Correct.
Has filter PCB 
RY001 or RY002 
relay activated?
 Has filter PCB 
AC fuse blown?
  Replace filter PCB.
Disconnect
U.V.W. output 
terminal on HIC PCB and 
start operation. 
Does alarm 
“P26”
occur?
 Replace HIC PCB.
Is
compressor OK? 
(Check for layer 
short circuit.)
 Replace compressor.
Is
resistance
between
each terminal on 
HIC PCB OK? 
(See following 
page.)
 Check HIC PCB.
 Replace if PCB 