Monessen Hearth CFX32 User Manual

Page of 36
10
CFX Vent Free Fireplace System
20301726
9”
Min.
9”
Min.
42”
Min.
FP2111a
min clearances
CLEARANCES and HEIGHT REQUIREMENTS
Ensure that minimum clearances shown in Figure 5 are maintained. Left and right clearances are deter-
mined when facing the front of the firebox.
Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may 
create a fire hazard.
1.  Sidewall Clearances — The clearance from the inside of the appliance to any combustible adjacent 
wall should not be less than 9". Figure 5
2.  Ceiling Clearance — The ceiling must be at least 42" from the top of the firebox opening. Figure 5
3.  Back Wall Clearance — The appliance may be placed against a combustible back wall.
Figure 5 - 
Clearances and Height Requirements
FP2111a
W
ARNING
The dimensions shown in Figure 5 are minimum clearances to maintain 
in installing this heater. Left and right clearances are determined when 
facing the front of the heater. 
Follow these instructions carefully to ensure safe installation. Failure 
to follow instructions exactly can create a fire hazard.