Ingersoll-Rand 650293-x Leaflet

Page of 1
E
2000 
D
 PRINTED IN U.S.A.
&
 (419) 636-4242 
D
 FAX (419) 633-1674
INGERSOLL-RAND  COMPANY
P.O. BOX 151
D
ONE ARO CENTER
D
BRYAN, OHIO 43506Ć0151
OPERATOR’S MANUAL
650293-X
RELEASED:
2-16-94
REVISED:
9-15-00
(REV. C)
650293-X METERING SYSTEM
USING 1” NON-METALLIC DIAPHRAGM PUMP
(PNEUMATIC COUNTDOWN TYPE)
INCLUDE MANUALS: 67072ĆX PNEUMATIC CONTROLLER ASM. (97999Ć596),
6661AXĆXĆC 1" NONĆMATALLIC DIAPHRAGM PUMP (97999Ć20)
MODEL
BASIC PUMP
FLUID SERVICE
KIT
DISP./ CYC
GAL. (CC)
650293Ć1
6661A3Ć344ĆC
637161Ć44ĆC
.165 (624)
650293Ć2
6661A3Ć3EBĆC
637161Ć44ĆC
.170 (643)
USE SERVICE KIT 637118ĆC FOR AIR SECTION REPAIR
GENERAL DESCRIPTION
The Pneumatic Controller Asm. provides logic control for preset disĆ
pensing. When installed on a diaphragm pump it can monitor the diaĆ
phragm pump pulse or cycle and to allow the user to accurately control
the number of cycles the pump will produce. This will effectively allow a
preset and repeatable amount of material to be dispensed through the
pumping system.
The 650293ĆX Series of Special 1" Diaphragm Pumps are similar to
Standard Models of 6661AXĆXXXĆC Diaphragm Pumps.
A 6661AXĆXĆC Operator's Manual is to be used for General InformaĆ
tion, Installation, Operation, and Maintenance.
Special Models and their Standard Model counterpart are shown in the
chart. Refer to the standard 6661AXĆXĆC Operator's Manual for SerĆ
vice Kits and other information.
Special parts involved in the model are shown below.
OPERATION
REFER TO 67072 PNEUMATIC CONTROLLER MANUAL FOR OPĆ
ERATION
NOTE: For best results operate the pump at 30 Ć 90 PSI (2 Ć 6.2 bar).
Fluctuations in the air pressure can affect the displacement per cycle.
Once the desired displacement is achieved, keep the air pressure as
constant as possible.
650293ĆX PUMP
SEE CHART ABOVE
67072 PNEUMATIC CONTROLLER
93911 ADAPTER PLATE
SPECIAL PARTS
FLUID INLET
FLUID OUTLET
AIR INLET
PN 97999Ć598