Patton electronic 1001MC User Manual

Page of 288
Creating and modifying global configuration templates
160
Model 1001MC Operations Guide 
7 • Model 2701RC management
The second part is the 
Unit Configuration
) for the configuration of the E1 link parame-
ters.  There are 16 configurable parameters.  What follows is a description of them with the available options 
for each.
Figure 78. Unit Configuration section of the web management table
Line Format
-
frame-G703(0)—This is called either Clear Channel or Transparent mode.  The DTE Rate is always 
2.408 Mbps and the Channel Assignment table does not affect the configuration when this option is cho-
sen.
-
frame-G704(1)—This is channelized mode.  When selected, the Channel Assignment table directly 
determines the DTE Rate.
DTE Rate
– There are no configurable options for this parameter, however it is affected by two configurable parame-
ters: the Line Format and the Channel Assignment table.
CRC Framing—Is applicable when the “frame-G704(1)” Line Format is chosen.
-
disabled(0)
-
enabled(1)
Line Build Out—This selects the electrical characteristics for the types of electrical connections, un-bal-
anced 75-Ohm coaxial cable or balanced 120-Ohm twisted pair cable.
-
lbo-75Ohm(0),  when using dual coaxial connections
-
lbo-120Ohm(1), when using twisted pair as the transmission medium
V54 Loop,  enables or disables the 2701RC’s ability to respond to a V.54 remote loop initiation pattern
-
disabled(0)
-
enabled(1)
Pattern Loop