Patton electronic 1001MC User Manual

Page of 288
Modem Information page MIB variables description
79
Model 1001MC Operations Guide 
5 • Model 1094ARC management
Note
Setting the Rack Protection Mode to normal(0) will enable the rack to 
receive new configurations through the global configuration command. 
Submit button
After you have defined the number of power supplies installed in the rack and the rack protection mode, click 
on the 
Submit
 button to save the changes.
Power Supply 1 Status
Displays the current status of power supply 1 as one of the following:
available(0)—The power supply is working normally.
down(1)—If the status is shown as down, it means the 1001MC is unable to detect the power supply. This 
status listing will also be highlighted in red.
notInstalled(2)—The power supply has not been installed.
Power Supply 2 Status
Displays the current status of power supply 2 as one of the following:
available(0)—The power supply is working normally.
down(1)—If the status is shown as down, it means the 1001MC is unable to detect the power supply. This 
status listing will also be highlighted in red.
notInstalled(2)—The power supply has not been installed.
Clear Rack X Alarms (clearAlarms)
Click on this button to clear alarms for the current rack. 
Note
The System Log will still display the errors after the 
Clear Rack 
Alarms
 button is clicked.
Note
The following information describes each column of the modem 
table. Each table heading is a hyperlink to a help page that contains 
information about the column.
Card Address (nmsSlotID)
This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed 
in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The 
address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the 
Model 
1095 Configuration Slot
 page. This page can be used to set slot-specific information about the card.
Line Status
The line status column on each 
View Rack 
page shows the current line status of each card. Keep in mind that 
the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the 
status of the line. The following values can be displayed:
startup(1)
dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data.