Sterling SSL User Manual

Page of 66
 
31 
BLOWBACK
 BLOWBACK Indicator 
The BLOWBACK indicator lights when the air solenoid is open. 
 
 
MATERIAL "B"
 MATERIAL “B” Indicator 
The MATERIAL “B” indicator lights when the Material B port is open. 
 
 
5-4  Starting Up the Hopper Loader for the First Time Using the 
Series One Plus Controller 
Non-Proportioning Models 
1.  Insert the pickup wand into the material supply. 
2.  Turn on the compressed air to the hopper loader. 
3.  Apply power to the controller.
 
Note: Press and hold the 
CLEAR
 
UP
 key and 
DOWN
 key together 
simultaneously while applying power to restore all factory 
defaults. 
 
As the controller powers up, the screen displays in succession: 
• 
PLUS
 for three seconds 
•  the software version number 
n.nn
 
•  the standby mode display. 
4. Press 
the 
S
START/STOP
 START/STOP/SELECT/SET key to start the 
hopper loader. 
The vacuum motor conveys material until the proximity sensor 
indicates the hopper loader is full or the factory-pre-set default 
maximum vacuum time of sixty seconds passes, whichever comes 
first. The VACUUM and MATERIAL “A” LEDs light and the 