Adjusting Proportioning On the Fly During Operation 
1.  While the hopper loader is operating, press the 
SCROLL
 SCROLL key 
until the screen displays the percent of Material B as 
P. nn
2. Press 
the   UP key or the 
 DOWN key to change the value 
as needed. 
3.   When the percentage of Material B you want displays, press the 
S
START/STOP
 START/STOP/ SELECT/SET key to set it. 
- or - 
Press the 
SCROLL
 SCROLL key to leave the menu unchanged. 
The screen then displays the Vacuum Timer menu. 
 
Note:  “On-the-fly” adjustments range between 1% and 99%. To set the 
percentage of Material B from 0% to 100%, stop the Series One 
Plus controller and reset proportioning while the unit is in 
Standby mode, as described in the previous section. 
 
5-7  Using the Batch Counter 
The Series One Plus controller features a batch counter you can view during operation. The 
batch counter provides a rough approximation of total material throughput. 
Viewing the Batch Counter 
While the hopper loader is operating and while the screen displays the vacuum timer display: 
 
„
  Press the 
SCROLL
 SCROLL key until the screen displays the four-digit 
batch counter. 
 
The screen remains on the batch count display until you press the 
SCROLL
 
SCROLL key again.