VENT INSTALLATION 
OPTIONAL TOP VENT APPLICATION 
The appliance is shipped as a rear vent unit. If the installation 
layout requires the unit to be a top vent configuration the appli-
ance can be converted by following the steps below.
When removing and refitting the plates and adapter be sure the 
associated gaskets are undamaged and refitted as required.
1.   Remove the eight (8) screws securing the flue pipe adapter 
to the fireplace body. See Figure 13. 
2.   Set the flue pipe adapter aside, complete with the gasket. 
Do not damage the gaskets as the adapter and gasket must 
be refitted.
3.   Remove the eight (8) screws securing the flue pipe cover to 
the top of the intake box and remove the cover and gasket. 
See Figure 13.
4.   Remove eight (8) screws securing the flue pipe to the 
back of the intake box and remove the pipe and gasket. 
See Figure 14.
5.   Replace flue pipe to top of firebox. Ensure the gasket is in 
place and undamaged.  Secure with eight (8) screws. See 
Figure 15.
6.   Place the flue pipe cover and gasket removed in step 3 over 
the flue opening in bottom of the intake box.
7.   Refit the flue pipe adapter and gasket to the top of fire-
place. Secure the adapter with eight (8) screws removed 
in step 1.
A f t e r   c o n v e r s i o n   t o   t o p   v e n t 
configuration the 4" (100mm) flue pipe 
should be concentric within the 6
5
/
8
(175mm) outer collar (within 
1
/
4
").
W
ARNING
Figure 13 - Removing sixteen (16) Screws from 
Flue Pipe Adapter and Flue Pipe Cover 
Figure 14 - Removing Flue Pipe
Figure 15 - Attaching Flue Pipe to Top 
Vent Configurations  
Screws 
Flue Pipe 
Cover 
Flue Pipe 
Adapter 
Flue 
Cover 
Flue Pipe 
Screws
Flue Pipe 