REAR WALL VENT INSTALLATION 
When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind 
the appliance
•   The maximum horizontal distance between the rear of the appliance and the outside face of the rear wall is 20" (508 m). 
See Figure 19.
•   Only one 45° elbow is allowed in these installations.
VENTING INSTALLATION     
Note:  Horizontal  runs  of  vent 
must be supported every three 
feet  (914mm).  Use  wall  straps 
for this purpose. 
Figure 21 - Rigid Vent Pipe Connections
Female 
Locking Lugs 
Male Slots
Figure 20 - Vent Opening Requirements 
1.  Locate and cut the vent opening in the wall. For 
combustible walls first frame in opening.    
Combustible Walls:
 
Cut a 11
1
2
"H x 9
1
2
" W (292mm 
x 24mm) hole through the exterior wall and frame as 
shown. See Figure 20.
 
Noncombustible  Walls:
 
Hole opening should be 
7
1
2
" (190mm) in diameter.
2.  Rigid vent pipes and fittings have special twist-lock 
connections. Assemble the desired combination of 
pipe and elbows to the appliance adaptor with pipe 
seams oriented towards the wall or floor.
 
Twist-lock Procedure:
 The female ends of the pipes 
and fittings have three locking lugs (indentations). 
These lugs will slide straight into matching slots on 
the male end of adjacent pipes and fittings. Push the 
pipe sections together and twist one section clockwise 
approximately one-quarter turn until the sections are 
fully locked. See Figure 21.
3.  Attach vent pipe assembly 