Hearth & Home Technologies CARDOG42I User Manual

Page of 39
 
Outdoor Lifestyles by Hearth & Home Technologies Inc.  •  Carolina •  4066-300  •  Rev. Q  •  7/11 
8
Framing
6 in. min.
82 in.
(2.08 m)
floor to ceiling
0 in.
Combustible Object
36 in.
(914 mm)
Front
Back
Note: If this surface is inside 
the building’s warm air 
envelope...
...then this surface must 
be an exterior wall 
system.
51-1/2 in.
(1.3 m)
63 in.
(1.6 m)
minimum
1-1/2 in.
(38 mm)
59-5/8 in.
(1.5 m)
82-1/4 in.
(2.1 m)
17 in.
(432 mm)
51-1/2 in.
(1.3 m)
1-1/2 in.
(38 mm)
1-1/2 in.
(38 mm)
Control
Box
Control
Box
50-1/2 in.
(1.28 m)
minimum
header height
50 in.
(1.27 m)
minimum
header height
71-3/4 in.
(1.82 m)
minimum
to top of cement
board
50 in.
(1.27 m)
17 in.
(432 mm)
Flashing
Cement Board
Control box
MUST be
relocated!
Exterior
Interior
11-1/2 in.
(292 mm)
minimum
36 in. minimum
(889 mm)
from appliance front
Side clearances can be zero at framing,
up to 6 inches deep 
6 in.
6 in.
Side clearances can be zero at framing,
up to 6 inches deep 
6 in.
6 in.
36 in. min. (914 mm)
cement board from 
the top of the firebox 
opening
36 in. min. (914 mm)
noncombustible
finishing material
8-1/4 in.
(210 mm)
10-5/8 in.
(270 mm)
36 in. minimum
(889 mm)
from appliance front
Note:  For actual appliance 
dimensions refer to Section 12.
Figure 3.2  Appliance Locations and Framing Dimensions - CARODG42I, CARODG42IL
NOTICE: 
Vinyl siding must 
not be placed between the 
fireplace opening and the 
ceiling/overhang.
NOTICE: 
Flash the perimeter of the fi replace, corners and 
the fi replace face in a manner consistent with regional 
practices as required to prevent water penetration around 
the  fi replace or manage water that may penetrate the 
fi replace. See Section 3.D. for more information regarding 
wall and enclosure construction.
E. Clearances and Framing Dimensions 
CARODG42I, CARODG42IL