4. FINAL OPERATIONS 
After replacing the nozzles, reposition the flame-spreader crowns, the 
burner caps and the grids. 
 
 
 
 
After adjustment to a different kind of gas from the one for which the 
cooker has been tested, replace the plate inside the storage 
compartment with one corresponding to the new kind of gas. This plate 
can be obtained from your nearest Authorised Assistance Centre. 
 
4.1 Adjustment of minimum for natural gas 
Light the burner and take it to the minimum. 
Remove the gas tap knob and turn the 
adjustment screw inside or at the side of the tap 
shaft (depending on the model) until there is a 
regular minimum flame. Replace the knob and 
check burner flame stability: (rapidly turning the 
knob from maximum to minimum position, the 
flame should not go out). Repeat the operation on 
all the gas taps. 
 
 
4.2 Positioning and levelling of the appliance 
 
Having carried out the electricity and gas hook-up, level the appliance 
using the four adjustable legs. 
 
4.3 Lubrication of gas taps 
 
With time it may happen that the gas taps get blocked and hard to turn. 
Clean them inside and re-grease them. This operation must be done 
by an authorised person.
 
 
 
 