RE105 
 
Temp Range, GE-Compatible 
 
Features 
 
Freeze and Overheat warnings. 
o
 
Can be used as just Freeze, just Overheat or both simultaneously. 
o
 
Unique ID’s for each function. 
 
Cover tamper. 
 
Strong, reliable RF signal. 
 
8-10 year battery life on CR123A battery. 
 
Low Battery indication. 
 
3.3x1.4x1.1 inches. 
 
Key Instructions 
 
Battery “+” faces towards spring. 
 
Enrolling: 
 
Freeze (1
st
 ID):  enrolled by tamper switch. 
 
This ID is on a label on the battery bucket. 
 
Overheat (2
nd
 ID):  enrolled by holding down tamper while 
installing battery. 
 
This ID is not on a label. 
 
Operation 
 
Freeze (1st ID) 
Alarm: when room temperature drops below 45F. 
Tamper: when cover is opened. 
Supervisory: every hour. 
 
 
Overheat (2
nd
 ID) 
Alarm: when room temperature rises above 100F. 
Tamper: when cover is opened. 
Supervisory: every hour. 
 
 
Custom temperatures available. 
RE105_GE_Temp_Instructions.doc 
Page 2 of 3 
5/4/2012 
www.ResolutionProducts.com
 
 
Specifications  
Freeze Alarm Temp: 
45F +/- 2F 
(custom temps available) 
Freeze Restore: 
when temp increases 4F from alarm 
Overheat Alarm Temp: 
100F +/- 2F  (custom temps available) 
Overheat Restore: 
when temp decreases 4F from alarm 
Mounting hardware: 
# 4 or #6 screws 
Replacement Battery: 
CR123A 1550 mAH 
Temperature Range: 
0F to 120F 
Housing dimensions: 
3.3x1.4x1.1 inches 
 