RE105
Temp Range, GE-Compatible
Features
•
Freeze and Overheat warnings.
o
Can be used as just Freeze, just Overheat or both simultaneously.
o
Unique ID’s for each function.
•
Cover tamper.
•
Strong, reliable RF signal.
•
8-10 year battery life on CR123A battery.
•
Low Battery indication.
•
3.3x1.4x1.1 inches.
Key Instructions
•
Battery “+” faces towards spring.
•
Enrolling:
Freeze (1
st
ID): enrolled by tamper switch.
•
This ID is on a label on the battery bucket.
Overheat (2
nd
ID): enrolled by holding down tamper while
installing battery.
•
This ID is not on a label.
Operation
•
Freeze (1st ID)
Alarm: when room temperature drops below 45F.
Tamper: when cover is opened.
Supervisory: every hour.
Tamper: when cover is opened.
Supervisory: every hour.
•
Overheat (2
nd
ID)
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened.
Supervisory: every hour.
Tamper: when cover is opened.
Supervisory: every hour.
•
Custom temperatures available.
RE105_GE_Temp_Instructions.doc
Page 2 of 3
5/4/2012
www.ResolutionProducts.com
Specifications
Freeze Alarm Temp:
45F +/- 2F
(custom temps available)
Freeze Restore:
when temp increases 4F from alarm
Overheat Alarm Temp:
100F +/- 2F (custom temps available)
Overheat Restore:
when temp decreases 4F from alarm
Mounting hardware:
# 4 or #6 screws
Replacement Battery:
CR123A 1550 mAH
Temperature Range:
0F to 120F
Housing dimensions:
3.3x1.4x1.1 inches
Specifications subject to change without notice.
Internal Picture
Temp Element