Vinotemp WM-25SFCL User Manual

Page of 25
                                                                                
- 7 -
Installer’s Instruction 
 
Federal law requires that WINE--MATE split cooling systems be 
installed by an EPA certified refrigeration technician. 
 
WINE-MATE split system is shipped as components and is ready for use only 
after a certified refrigeration technician has properly installed, charged and tested 
the system. Proper installation is critical. Vinotemp can only warrant the quality of 
the components. The installation and proper operation of the system must be 
warranted by the installer. Installation of the system must be done in accordance 
with all state and local building codes.  
The condensing unit and evaporator unit are connected by a liquid line and an 
insulated suction line that are supplied by the installer. These lines must be 
properly sized for the distance between the two units. After the units and the lines 
are installed, the system must be pressure tested. If no leaks are found, 
evacuate and charge system with R134A. Refrigerant amount will vary 
depending on the length of line set. 
 
Fig. 2.1 SSL Split System Installation