KitchenAid 2314464 User Manual

Page of 56
18
Base Grille Water Filtration System 
Model WF-NLC120V Capacity 120 Gallons (454 Liters)
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of 
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for 
water leaving the system, as specified in ANSI/NSF 42/53.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F 
(17.2°C).
It is essential that operational, maintenance, and filter 
replacement requirements be carried out for the product to 
perform as advertised.
Model WF-NLC120V: Change the water filter cartridge every 
6-9 months. Use replacement cartridge NLC120V, part 
#4396701. 2005 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of 
unknown quality without adequate disinfection before or after 
the system. Systems certified for cyst reduction may be used 
on disinfected waters that may contain filterable cysts. 
Refer to the front cover or “Accessories” section for the 
Manufacturer’s name, address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited 
warranty. 
Application Guidelines/Water Supply Parameters
Substance Reduction
Aesthetic Effects
NSF Reduction 
Requirements
Average
Influent
Influent Challenge 
Concentration
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average% 
Reduction
Chlorine Taste/Odor
Particulate Class l
*
50%
85%
1.9 mg/L
5,300,000/mL
2.0 mg/L ± 10%
At least 10,000 particles/mL
0.12 mg/L
50,000/mL**
0.08 mg/L
15,725/mL
>75%
99.0%
>75%
99.7%
Contaminant
Reduction
NSF Reduction 
Requirements
Average
Influent
Influent Challenge 
Concentration
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average% 
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.01mg/L
0.01mg /L
0.14 mg/L
0.15 mg /L
0.15 mg/L ± 10%
0.15 mg /L ± 10%
0.001 mg/L
0.001 mg/L
0.001 mg/L
0.001 mg/L
99.29%
99.32%
99.29%
99.32%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.0058 mg/L
0.0055 mg/L
0.006 mg/L ± 10%
0.006 mg /L ± 10%
0.0005 mg/L
0.0013 mg /L
0.0003 mg/L
0.0005 mg/L
91.37%
76.36%
94.82%
90.90%
Benzene
0.005 mg/L
0.0153 mg/L
0.015 mg/L ± 10%
0.0036 mg/L
0.0014 mg/L
76.47%
90.84%
p-dichlorobenzene
0.075 mg/L
0.215 mg/L
0.225 mg/L ± 10%
0.0037 mg/L
0.0010 mg/L
98.27%
99.52%
Asbestos
99.0%** 
842 x 10
7
10
to 10
fibers/L
††
1.6 x 10
7
 mg/L
1.6 x 10
7
 mg/L
99.81
99.81%
Cysts
 ‡
Turbidity
99.95%
0.5 NTU
165,500/mL
11.75 NTU
50,000/L min.
11 ± 1 NTU
1 mg/L
0.38 NTU
1 mg/L
0.22 NTU
99.99%
96.76%
99.99%
98.12%
Endrin
0.002
0.0056
0.006 ± 10%
0.0007
0.0004
87.50
92.85
O-Dichlorobenzene
0.60
1.84
1.8 ± 10%
0.33
0.071
82.06
96.14
Toxaphene
0.003
0.0143
0.015 ± 10%
0.001
0.001
93.00
93.00
Ethyl Benzene
0.70
2.00
2.1 ± 10%
0.60
0.169
70.00
91.55
1,2,4- trichlorobenzene 0.07
0.232
0.21 ± 10%
0.0025
0.0007
98.92
99.69
System tested and certified by NSF International against NSF/ANSI
Standard 53 for the reduction of Lead, Mercury, Benzene, 
p-dichlorobenzene, Cysts, Turbidity, Asbestos, Endrin, 
O-Dichlorobenzene, Toxaphene, Ethyl Benzene, 1,2,4-trichlorobenzene 
and against NSF/ANSI Standard 42 for the reduction of Chlorine Taste 
and Odor and Particulate Class I.
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 GPM (1.89 L/min.) @ 60 psi.
*
**
††
Class I particle size: >0.5 to <1 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.