KitchenAid W10121528A User Manual

Page of 24
4
Dimensions and Cabinet Requirements
NOTES: 
1
³⁄₈" (3.5 cm) diameter opening is required in the sink or 
countertop. 
Thickness of the sink or countertop must not exceed 1
³⁄₄" 
(4.4 cm).
Electrical Requirements
A 120-volt, 60 Hz, AC-only 15- or 20-amp fused, grounded 
electrical supply is required. It is recommended that a separate 
circuit serving only the hot water dispenser be provided. Use an 
outlet that cannot be turned on/off with a switch.
Recommended Grounding Method
This hot water dispenser must be grounded. This hot water 
dispenser is equipped with a power supply cord having a 3 prong 
grounding plug. To minimize possible shock hazard, the cord 
must be plugged into a mating, grounded 3 prong outlet, 
grounded in accordance with all local codes and ordinances. If a 
mating outlet is not available, it is the customer's responsibility to 
have a properly grounded 3 prong outlet installed by a qualified 
electrical installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 - 
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
A. Tank—mounted vertically
B. Model series KHWG260 faucet
C. 11
¹⁄₄
" (28.5 cm)
D. 7
⁹⁄₁₆
" (19.2 cm)
E. Saddle valve or hard-plumbed 
connection to water supply line
F. 7
⁷⁄₈
" (20 cm)
G. Model/serial number label
H. 42" (106.7 cm) maximum from 3 prong outlet 
to water dispenser tank
I. Cold water supply line
D
F
C
E
G
B
A
I
H
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING