EMI S1C 30-36 User Manual

Page of 4
S1CA/S1HA ductless Split System Single-Zone
www.enviromaster.com
1
Specification
S
 and 
p
erformance
Nominal Circuit Capacities S1C/S1H: 9,000, 12,000, 
18,000, 24,000 Btuh and S1C 30-36 Btuh
EMI offers the AmericaSeries S1C/S1H single zone con-
densing unit, which is designed to meet or exceed a SEER 
rating of 13.0  when installed with the AmericaSeries line 
of evaporators. The system is offered for straight cool and 
heat pump applications and is available in nominal circuit 
capacities  of  9,000,  12,000,  18,000  and  24,000  Btuh  for 
both  cooling  and  heat  pump  and  30,000-36,000  Btuh  for 
cooling  only  applications.  The  S1C/S1H  system  can  be 
recommended for both commercial and residential use.
S1c/S1H 9-24 and S1c 30-36
SinGLe Zone ductLeSS SpLit 
condenSinG unit
 P/N 240005841, Rev. A  [05/08]
  Low Ambient  cooling  operation 
down  to  32º  F  are 
standard  on  all  S1H  (heat  pumps) 
factory  installed 
(optional on S1Cs) 
•  Low Ambient  cooling  operation  down  to  32º  F                 
–  Specify  this  option  if  the  S1C  system  will  be 
operated in cooling mode at outside temperatures 
below 60º F (Field Installed kit) 
•  Low  Ambient  controls  for  operation  down  to                     
0º F for S1C and S1H systems (consult factory for 
availability)
• Hard Start
• 115v (9,000-12,000 Btuh only)
• Copper/copper coils (sea coast use)
Precharged for Condenser and evaporator: 
(Charging of field installed piping required)
• Refrigeration valves – solid brass, sweat connection, 
easy to access ports
• Up to 100’ length  interconnect (including 35’ verti-
cal lift)
Duratec Performance Package (09-12 only)
• Oversized suction accumulator with surge baffles and 
enhanced oil management
• Factory installed solid core filter drier
• Thermostatically controlled crankcase heater 
(heat pump)
• High pressure switch (heat pump)
Benefit: The Duratec performance package allows 
for  the  widest  range  of  application  in  the  Ductless 
Split industry. We fully protect the compressor for a 
range of outdoor ambient conditions and system ap-
plications, which extends the life of the system and 
virtually eliminates failures.
SyStem OptiOnS
Benefit: The U-shaped coil optimizes the heat transfer 
surface in a smaller footprint to gain optimum system 
efficiency. 
COndenSer StAndArd FeAtureS
prOduCt deSCriptiOn
Benefit: These are the most efficient (power saving) and 
durable compressors available for the widest range of 
Ductless Split system applications.
fan/Motor 
- Fan is a large diameter, high efficiency, 
three or four blade propeller (depending on capacity). 
Motor is PSC type with internal overload protection. 
Cabinet 
• Vertically arranged side discharge
• Scratch and dent resistant injection molded front 
access panel
• Powder coated  (2000 hour salt spray tested) 18 and 
20 gauge aluminized steel
• Recessed service valves
• Easy access hose connections at 45° from valve body
Compressor
 is hermetically sealed high efficiency rotary 
for  9,000-12,000  Btuh  and  reciprocating  or  scroll  for 
18,000-36,000 Btuh (depending on capacity).
Coil
 is U-shaped and protected by a wire coil guard.  
Construction is seamless copper tubing with enhanced 
aluminum fins. The tubes are mechanically expanded 
for secure bonding to fin shoulder. 
COndenSer StAndArd FeAtureS cont.
Thermostatically  controlled  crankcase  heater  – 
This feature energizes the crankcase heater only when 
needed, removes the heater from the electrical circuit 
at conditions where it’s not required, saving unneces-
sary Watts, and increasing overall system efficiency.