Perlick H50IMS-ADL User Manual

Page of 31
26
3. Sanitizing Solution
IMPORTANT
For safety and maximum effectiveness, use the solution immediately after 
dilution.
Dilute 0.5 fl. oz. (14.8 ml or 1 tbs) of a 5.25% sodium hypochlorite solution (chlorine 
bleach) with 1 gallon (3.8 l) of warm water. This is a minimum amount. Make more 
solution if necessary. Using a chlorine test strip or other method, confirm that you have a 
concentration of about 200 ppm.
4. Sanitizing Procedure
1) Make sure the control switch is in the "OFF" position and the storage bin is empty.
2) Remove the slope from the storage bin by carefully bending it in the center and 
releasing it from the 2 slope shafts. See Fig. 28. 
3) Remove each separator by lifting it to the horizontal position and pushing it hard inward. 
See Fig. 29.
4) Disconnect the suction tube. Allow the water tank to drain.
5) Spread out the tabs to unlock the water tank, then slide it out. See Fig. 30.
6) Lift off the ice chute from the front frame pipe and then from the rear frame pipe. See 
Fig. 31.
Separator
Ice Chute
Front Frame Pipe
Tab
Tab
Slope
Fig. 28
Fig. 29
Fig. 30
Fig. 31
Rear Frame Pipe
Slope Shafts
Water Tank