4.  FINAL OPERATIONS 
After changing the nozzles, put the pan stands, the burner caps and 
flame diffuser rings back in place. 
 
 
 
After adjusting for use of a gas other than the gas used for testing the 
appliance, replace the gas setting label on the appliance with the label 
for the new gas. The label is supplied in the bag with the nozzles. 
 
4.1  Adjusting the minimum setting for town gas and natural 
gas 
Light the burner and turn it to the minimum 
setting    Remove the gas tap knob and adjust the 
regulator screw inside or beside the tap rod 
(depending on the model) until an even minimum 
flame is obtained. Put the knob back in place and 
check the stability of the burner flame (the flame 
must not go out when the knob is turned quickly 
from the maximum to the minimum setting).  Repeat 
the operation on all the gas taps. 
 
4.2 
4.3
Adjusting the minimum for bottled gas 
To adjust the minimum level when using bottled gas, the adjuster screw 
inside or beside the tap rod must be turned fully clockwise (depending on 
the models). 
The diameters of the bypasses for each individual burner are stated in 
point "3.2 Burner and Nozzle Data Tables". 
 
 
Fitting the rear splash-back 
 
 
• 
Place the splash-back on the hob, aligning the holes with the holes
B
• 
Fix the splash-back to the hob by tightening the screws C