GE JKP25SH User Manual

Page of 3
GE Appliances
JKP25SH – GE® 27" Built-In Single Oven 
Installation Information: Before installing, consult installation 
instructions packed with product for current dimensional data.
27" Built-In Single Oven Dimensions (in inches)
Specification Revised 7/05
320431
2" x 4" 
or equiv.
runners
B MIN.
C MIN.
Conduit 48-1/2" long
6015 Built-in Single Oven  
(Pub. 1-G003 pg. 107) April 28, 1993
32-1/2
D
10
A
Allow 3/4"
for overlap
over all edges
of cutout
Locate
junction box
either 5" MIN.
below cutout
floor or 44"
MIN. above 
cutout floor
Minimum
cutout location
from floor
(Minimum 15-5/8"
from floor when
installed below built-in
microwave oven)
E
G
F
20
Note: These ovens are not 
approved for stackable or  
side-by-side installations.
Note: These ovens can be 
installed side-by-side with no 
less than 30" distance between 
center-to-center of each oven.
Note: Cabinets installed adjacent to wall ovens  
must have an adhesion spec of at least a 194°F  
temperature rating.
Note: For 27" built-in single ovens, if marks, 
blemishes or the cutout opening is visible  
above the installed oven, it may be necessary  
to add wood shims under the runners and front 
trim until the marks or openings are covered.
Cabinet 
 
27"
  A – Cabinet Width Required 
27" min.
  B – Minimum Cabinet Depth 
23-5/8"
  C – Opening Width 
25" min. - 25-1/4 max. 
  D – Opening Height  
27-5/8" min. - 28-1/8 max.
Oven
  E – Overall Depth 
23-5/8"
   
w/o trim 
28-1/4"
  F – Overall Height  with trim 
29"
  G – Overall Width 
26-5/8"
 
CL
Suitable
bracing 
to support
runners
18" 
Over centerline
of cabinet
2" x  4" or
equivalent
runners
(Must support 275 lbs.)
R
Listed by 
Underwriters 
Laboratories
For answers to your Monogram,® GE Profile™ or 
GE® appliance questions, visit our website at
GEAppliances.com or call  
GE Answer Center® service, 800.626.2000.
 
 KW Rating
  240V
 
3.4
  208V 
2.6
Breaker Size
  240V
 
20 Amps
  208V 
20 Amps
Electric wall ovens are not approved for installation with a plug and receptacle. 
They must be hard wired in accordance with installation instructions.