Electrical connection
Operation and function
Mechanical controls
In addition to a thermostat knob, the control 
panel contains two control lamps and a but-
ton (fig. 4). Control panel design and lamp 
position may vary.
The green lamp is lit when power is cor-
rectly supplied.
The yellow lamp is lit when the Super 
Freeze button has been pressed (see Super 
Freeze).
Starting up
Connect the appliance to the socket outlet. 
The green lamp lights up to indicate that 
power is supplied. The red lamp on the con-
trol panel will also light up to indicate that 
the temperature inside the freezer is not yet 
sufficiently low.
Temperature setting
The temperature is set by turning the 
thermostat knob from MIN to MAX. It is 
recommended that a coin be used to turn 
the knob. The more the thermostat knob is 
turned towards MAX, the lower the tempera-
ture. To test whether the setting is correct, 
measure the temperature of the uppermost 
item in the centre of the freezer.
It must be no warmer than –18 °C.
Super Freeze
If more than 3 kg of fresh items are to be 
frozen, proceed as follows:
1. Press the Super Freeze button (the 
yellow lamp lights up). The freezer then 
operates at maximum capacity (the com-
pressor runs continuously).
2. Activate Super Freeze 24 hours before 
placing fresh items in the freezer.
3. After placing fresh items in the freezer, 
leave Super Freeze on for a further 24 
hours.
4. Then press the Super Freeze button 
again (the yellow lamp goes off).
Acoustic alarm
When plugging in the unit an acoustic alarm 
will activate. Push the yellow button to 
deactivate the alarm. Notice that the alarm 
must be activated again after 24 hours by 
pushing the yellow button.
-18
fig. 4