Bunn RL00006929 User Manual

Page of 32
Page 14
FIG. 2 CONTROL THERMOSTAT
FIG. 3 THERMOSTAT WIRING
SERVICE (cont.)
Control Thermostat
Location:
 
The control thermostat is located under the top 
cover or top warmer housing, FIG. 2.
 
To test the control thermostat, access will also 
be needed to the tank heater located in the bottom of 
the tank assembly.
Test Procedure:
1.  Disconnect the brewer from the power source.
2.  Check the voltage across the blue wire on the 
control thermostat and the white or red wire on 
the tank heater with a voltmeter.  Connect the 
brewer to the power source.  The indication must 
be:
 
a) 120 volts ac for two wire 120 volt models.
 
b) 200 or 240 volts ac for two wire 200 volt or 
240 volt models and three wire 120/240 volt 
models.
 
c) 100 volts ac for two wire 100 volt models.
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the Wir-
ing Diagrams and check the brewer wiring harness.
4.  Check the voltage across the black wire terminal 
of the control thermostat and the white or red 
wire on the tank heater with a voltmeter when 
the control thermostat is turned “ON” (fully 
clockwise).  Connect the brewer to the power 
source.  The indication must be as described in 
step 2.  Voltage must not be indicated across 
these terminals when the thermostat is turned 
“OFF” (fully counterclockwise).
5.  Disconnect the brewer from the power source.
If voltage is present as described, the control thermo-
stat is operating properly.
If voltage is not present as described, replace the 
control thermostat.
Removal and Replacement:
1.  Remove the top cover or top warmer housing 
from the brewer to gain access.
2.  Remove both wires from the control thermostat 
terminals.
3.  Remove the thermostat bulb by firmly pulling-
up on the capillary tube at the tank lid.  This will 
disengage the grommet from the tank lid.
4.  Remove the two #8-32 screws holding the control 
thermostat to the bracket.
5.  Fasten the new control thermostat to the compo-
nent bracket.
NOTE - Make sure that the capillary tube is away from 
any electrical termination and is not kinked.
6.  Slide the grommet to the red mark on the capillary 
tube.
7.  Insert the bulb through the hole in the tank lid 
and press the grommet firmly and evenly so that 
the groove in the grommet fits into the tank lid.
8.  Carefully bend the capillary tube so that the tube 
and bulb inside the tank are in a vertical posi-
tion.
9.  Refer to FIG. 3 when reconnecting the wires.
10.  Readjust the control thermostat dial as re-
quired.
BLU to Limit Thermostat 
 
BLK to Tank Heater
P1478
P1098
32430 121699