GE ZEU36KSK/WK/BK Leaflet

Page of 2
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service, 
800.626.2000.
Listed by 
Underwriters 
Laboratories
Dimensions and Installation Information (in inches)
R
557ZEU669
16" Min
Junction
Box
 21-1/4" at  
center
1-3/4"
Min.
*3-1/4"
36"
33-7/8"
2-1/2" 
Min. 
to  Front 
Edge
19-1/8"
2" Min. 
to Side Walls
605Dia128
Combination Installations 
Consideration must be given to the electrical supply  
locations when the cooktop is installed with other  
products in the same cabinet. Always refer to each  
product's installation instructions for clearances  
and electrical requirements.
• Install these cooktops with any exhaust hood of the  
  same or greater width; 300 CFM or greater air flow. 
• The cooktop may be installed with a 36" Monogram  
  downdraft vent. 
Electrical Requirements 
Product rating is 120/208V or 120/240V, 60Hz. For 240V,  
connect to a 40-amp circuit; connect to a 30-amp circuit  
for 208V operation. The cooktop must be connected to  
a supply circuit of the proper voltage and frequency and 
protected by a time-delay fuse or circuit breaker. 
* 3-1/4" deep at the front. 4-5/8" deep at the rear conduit location. 
Allow 5" minimum clearance below the cooktop bottom to  
combustible materials. 
Specification Created 12/04
130250
ZEU36KSK/WK/BK 
GE Monogram
®
 36" Ribbon Cooktop