Smeg PTSA605-3 User Manual

Page of 16
Instructions for the Installer
 
 
 
3. 
Electrical connection 
 
 
Check that the power supply line voltage and size are as specified on the nameplate 
underneath the appliance's casing. This nameplate must never be removed. 
 
 
 
The plug on the end of the power supply lead and the wall socket must be of the same 
type and comply with the relevant regulations. Check that the power supply line is 
properly earthed. 
 
 
 
Pass the power supply cable through the rear of the cabinet, taking care that it does not 
touch the bottom case of the hob, or the oven (if any) built in underneath it. 
 
 
 
The appliance's power supply line must be fitted with an omnipolar breaking device with 
contact gap of at least 3 mm, located in an easily accessible position close to the 
appliance itself. 
 
 
 
The use of reductions, adapters or junctions is not recommended. 
 
 
 
 
 
 
If the power supply cable has to be replaced, the gauge of the wires in the new cable must 
be at least 0.75 mm
2
 (3 x 0.75 cable), bearing in mind that the earth wire (yellow-green) 
must be at least 20 mm longer at the end for connection to the appliance. Use only a type 
H05V2V2-F or similar cable resistant to a temperature of up to 90°C. The cable must be 
replaced by a qualified electrician, who must make the mains connection as shown below. 
 
L = brown 
N = blue 
 = yellow-green
 
 
 
 
 
 
 
 
The power supply lead must be replaced by an authorised service centre to prevent all 
risks.
 
 
 
 
 
The manufacturer declines all responsibility for injury or damage caused by failure to 
comply with the above regulations or deriving from tampering with even just one part 
of the appliance.