Cleveland Range 36-CGM-16-300 Leaflet

Page of 2
Cleveland
Project  ________________________________
Item  __________________________________
Quantity  _______________________________  
FCSI Section  ____________________________
Approval  _______________________________
Date  __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110 
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com  
 
CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE
MODEL
 36-CGM-16-300
Cleveland Standard Features
I
I
Cooking Capacity for up to eight 12˝ x 20˝ x 2
1
2
˝ deep
Cafeteria Pans per compartment, or four 18˝ x 26˝ Buns Pans.
I
I
Pressureless cooking with forced convection steam,  permitting
doors to be opened while cooking continues.
I
I
Solid State Controls operate water level and safety functions.
I
I
Each compartment is equipped with a 60 minute mechanical
timer, separate bypass switch for constant steaming.
I
I
Instant Steam Standby Mode: Holds generator at steaming
temperature. Allows unit to start cooking instantly.
I
I
Durable 10 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
I
I
Separate Main Power Switch for “On/Off”
I
I
Exclusive Steam Cooking Distribution System: The exclu-
sive Convection Jets produce a high velocity  convection steam
without fans. Coved Corner design in  cooking compartment dis-
tributes heat evenly and is easy to keep clean. Creased bottom
enhances drainage. Cold Water Condenser for each compart-
ment maintains a dry steam. Fully insulated cooking compart-
ment for thermal efficiency. Removable Stainless Steel Slide
Racks for easy cleaning.
I
I
Heavy duty, one piece, solid compartment door design
with replaceable door gasket
I
I
Left Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
I
I
Modular Cabinet Base with Hinged Door.
I
I
Heavy duty Stainless Steel Base Frame.
I
I
High Efficiency Gas Steam Generator with NickelGuard,
Electronic Spark Ignition and Automatic Water Fill on start up.
I
I
Automatic Generator Drain at shutdown: Contains a “Water
Jet” Spray Rinse Cleaning Cycle to keep drain clear.
I
I
Automatic Water Level Control System with Low Water
Power Cut-off Circuit.
I
I
Steam generator equipped with High Limit Pressure Safety
Switch, 15 psi Safety Valve, and Steam Generator Pressure
Gauge.
I
I
NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
I
I
Gas Pressure Regulator and Control Valve.
I
I
Standard Voltage for Control: 115 volts, 60 Hz, single phase.
I
I
All Controls are serviceable from the front.
I
I
Compartment Door Steam Shut Off Switch.
Options & Accessories
Ë Electronic Timer with Compensating Load Feature. (ETC)
Ë ON/OFF Steam Switch only for compartment controls (MC)
Ë Cafeteria pans in depths of 1˝, 2
1
2
˝, 4˝ and 6˝
Shall be Two Large Compartments, CLEVELAND Convection Steamer,  Gas-
fired Steam Generator, Model 36-CGM-16-300, NickelGuard, 300M BTU,
_____ gas, _____ volts, _____ Hz, single phase. Solid State Controls operate
timing, water level and safety functions.Type 304 Stainless Steel cooking
compartment. Insulated cooking compartments. One 60 minute Mechanical
Timer with Touch Control per compartment. Audible and Visual Signals for
cycle completion and steam shut-off.
Ë 18˝ x 26˝ Bun Pans
Ë Stainless Steel Insulated Flue Cover (SSF)
Ë Quick Disconnect for gas line (QDC)
Ë Correctional Packages
Ë Secondary Low Water Cut-Off, factory installed (CALG)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI.
MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY,
Wash. DC)
Ë Boiler Descaling Pump Kit (107142)
Ë Water Filters
Ë Rear Gas Connection (RGT)
Short Form Specifications
Shown with optional
Electronic Timer
ConvectionPro XVI
®
TWO LARGE COMPARTMENTS, PRESSURELESS
300M BTU GAS FIRED STEAM GENERATOR
36” WIDE CABINET BASE DESIGN, with NICKELGUARD™
CONVECTION
STEAMERS
1
0
0
%
5
Ye
ar Boiler
W
a
rr
a
n
ty
N
ic
ke
lGuar
d
SECT.
III
PAGE 
27
1007