Fujitsu M4000/M5000 User Manual

Page of 42
32
SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1060 • November 2007
8. Update the firmware by using the flashupdate(8) command.
Caution – 
flashupdate
(8) will update one bank, reset the XSCF and commence 
update of the second bank. Verify that the current and reserve banks are both 
updated. If both banks indicate XCP revision 1060, proceed to the next step.
Specify the XCP version to be updated. In this examples, it's 1060.
9. Confirm completion of the update.
Confirm no abnormality happens while updating.
10. Confirm that both the current and reserve banks of XSCFU#0 display the updated 
XCP versions.
If the Current and Reserve banks on XSCF#0 do not indicate XCP revision 1060, 
contact your authorized service representative.
11. Confirm no abnormality occurred by using showlogs error -v and 
showstatus
(8) commands.
If you encounter any hardware abnormality of the XSCF contact your authorized 
service representative.
12. Power on all domains.
XSCF> flashupdate -c update -m xcp -s 
version
XSCF> showlogs event
XSCF> version -c xcp
XSCF#0 (Active)
XCP0 (Reserve): 1060
XCP1 (Current): 1060
XSCF> showlogs error -v
XSCF> showstatus
XSCF> poweron -a