Sony 8000SF User Manual

Page of 591
414
Key Setting Operations With the Key Control Block
  
 Chap
Masks
Using the main mask
In the key control block, press the [MAIN MASK] button, turning it on. The 
parameter settings depend on the mask source selected as [Box] or [Pattern] in 
the <Mask Source> group of the Main Mask menu for the key.
• When box is selected
When box is selected and the [MORE] button is lit amber, there are more 
settings. Press the [MORE] button, so that it changes from amber to green to 
make the extra setting.
• When pattern is selected
a) The pattern is the same as a standard wipe. (See “Wipe Pattern List” in Appendix (Volume 1) 
Using the subsidiary mask
In the key control block, press the [SUB MASK] button, turning it on. The 
parameter settings depend on the mask source selected as [Wipe] or [Utility 1 
Bus] in the <Mask Source> group of the Sub Mask menu for the key.
3
Hue
Hue
359 to 0
4
Density
Density
0 to 100
Knob
Parameter
Adjustment
Setting values
Knob
Parameter
Adjustment
Setting values
1
Top
Top position
–100 (shown as –00) to +100
2
Left
Left position
–100 (shown as –00) to +100
3
Right
Right position
–100 (shown as –00) to +100
4
Bottom
Bottom position
–100 (shown as –00) to +100
Knob
Parameter
Adjustment
Setting values
1
Soft
Box softness
0 to 100
Knob
Parameter
Adjustment
Setting values
1
Size
Pattern size
0 to 100
2
Soft
Edge softness
0 to 100
3
Pattern
Pattern number
1 to 24 
a)