3M 800ab User Manual

Page of 122
17 
2010 December
800ab-NA 
A tool kit containing some tools are supplied 
with the machine. These tools should be 
adequate to set-up the machine, however, 
other tools supplied by the customer will be 
required for machine maintenance.
7.3  Tool Kit Supplied with the Machine
7.4  Machine Set-Up / Bed Height
Figure 7-2
Adjust machine bed height. The case sealer is 
equipped with four (4) adjustable legs that are 
located at the corners of the machine frame. The 
legs can be adjusted to obtain different machine bed 
heights from 610mm [24 inches] minimum to 890mm 
[35 inches] maximum - See Specifi cations.
Refer to Figure 7-3 and set the machine bed height 
as follows:
1.  Raise and block up the machine frame to allow 
 
adequate leg adjustment.
2.  Loosen, but do not remove, two (2) M8 x 16mm
 
socket head screws in one leg (use M6 hex 
 
wrench). Adjust the leg length for the desired 
 
machine bed height. Retighten the two screws 
 
to secure the leg. Adjust all four (4) legs equally.
7.1  Operating Conditions
The machine should operate in a dry and relatively
clean environment (See Specifi cations).
7.2   Space Requirements for Machine Operation
 
and Maintenance Work
Minimum distance from wall (Figure 7-1):
A =  1000mm.
B  =    700mm.
Minimum height = 2700mm.
7-INSTALLATION
Figure 7-1
Figure 7-3
M8 x 16mm
Socket Head 
Screws
Adjustable
Leg
•  To reduce the risk associated with 
  mechanical and electrical hazards:
−  Allow only properly trained and 
 qualifi ed personnel to operate and service 
 this 
equipment.
WARNING
• 
To reduce the risk associated with 
 muscle 
strain:
− 
Use the appropriate rigging and 
 
material handling equipment when 
 
lifting or repositioning this equipment.
 − 
Use proper body mechanics when 
 
removing or installing taping heads 
 
that are moderately heavy or may be 
 
considered awkward to lift.
WARNING