APC ES 350G User Manual

Page of 6
Back-UPS
®
 ES 350G
User Guide
1
2
3
Connect Battery
Equipment
Turn on the Unit
Surge Protection
These outlets provide full-time protection from surges even if the 
Back-UPS ES is switched OFF. Plug your printer, fax machine, 
scanner, or other peripherals that do not need battery power into 
these outlets.
Battery Back-up +
Surge Protection
These outlets are powered whenever the Back-UPS ES is 
switched ON. During a power outage or other utility problems 
(brownouts, over-voltages), these outlets will be powered for a 
limited time by the Back-UPS ES.  Plug your computer, 
monitor, and other peripheral devices into these outlets.
Press the ON/OFF switch to turn on the unit.
A single short beep and the green “Power On” indicator 
confirms the Back-UPS ES is on and ready to provide 
protection.
The Back-UPS ES should charge for at least 16 hours to 
ensure sufficient runtime. The unit is being charged whenever 
it is connected to utility power, whether the unit is turned ON 
or OFF.
If the red Building Wiring Fault indicator (located on the end 
near the power cord) is lit, your building wiring presents a 
shock hazard that should be corrected by a qualified 
electrician.
w
 
w
 
w.apc.com
®
The Back-UPS ES indicates operating status using a combination of visual and audible 
indicators. Use the following table to identify the status of the Back-UPS ES. 
Status
Visual Indication
Audible Alarm
Alarm Terminiation
Power On - UPS is 
supplying conditioned utility 
power to the load.
Power On pushbutton  
- ON (lit)
None
Not applicable.
On Battery - UPS is 
supplying battery power to 
the load connected to the 
Battery outlets.
Power On pushbutton  
- ON (off during beep)
Beeping 4 times every 
30 seconds
UPS transfers back to 
Power On operation, or 
when UPS is turned off.
Low Battery Warning 
UPS is supplying battery 
power to the load 
connected to the battery 
outlets, and the battery is 
near exhaustion.
Power On indicator is 
flashing 
Rapid beeping (every 
1/2 second)
UPS transfers back to 
normal operation, or when 
UPS is turned off.
Replace Battery - The 
battery is disconnected.
The battery is in need of 
charging, or is at the end of 
its usual life and must be 
replaced.
Replace Battery 
indicator is Flashing 
Power On and Replace 
Battery indicators -  
flashing (alternating) 
Constant tone
Constant tone
UPS is turned off with the 
power switch.
Overload Shutdown 
During On Battery 
operation a battery power 
supplied outlet overload 
was detected.
None
Constant tone
UPS is turned off with the 
power switch.
Sleep Mode - During On 
Battery operation the 
battery power has been 
completely exhausted and 
the UPS is waiting for utility 
power to return to normal.
None
Beeping once every 4 
seconds
Utility power is restored, or 
if utility power is not 
restored within 32 seconds, 
or the UPS is turned off.
Building Wiring Fault - 
Your building wiring 
presents a shock hazard 
that should be corrected by 
a licensed electrician.
Building Wiring Fault 
LED (red) - ON
None
UPS is unplugged, or UPS 
is plugged into a properly 
wired outlet.
Status Indicators
For safety, the Back-UPS ES is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe 
battery terminal.  NOTE: Small sparks may occur during battery connection. This is normal.
Turn the Back-UPS ES over and press in the 
release tab. Slide the plastic battery cover 
off of the Back-UPS.
Insert the battery back into the compartment. 
Slide the plastic battery cover until the release 
tab locks into place. 
Connect the battery wire firmly to the  
battery terminal. 
1
2
3
Connect
Connect Modem / Phone / DSL / Fax 
The Back-UPS protects a single line (2-wire) phone (including Digital Subscriber Line - 
DSL), Home Phoneline Networking Association (HPNA) type equipment, modem, or fax 
machines from surges when connected through the UPS as shown in the drawing below.
Place the Back-UPS ES to avoid:
 - Direct sunlight
 - Excessive heat
 - Excessive humidity or contact with fluids
Plug the Back-UPS ES power cord directly into a wall outlet; not into a surge 
protector or power strip.
4
Transfer Voltage and 
Sensitivity Adjustment 
(Optional)
In situations where the Back-UPS, or connected equipment, is too 
sensitive to the input voltage, it may be necessary to adjust the 
transfer voltage.  To adjust the transfer voltage:
1. Plug the Back-UPS into the utility power source. The Back-
will be in “Standby mode” (no indicators are lit). 
2. Press the ON/OFF push button fully in for 10 seconds. The 
Online LED will begin glowing in a cyclical order: GREEN- 
AMBER-RED, indicating it is going into “Program mode”. 
3. The Back-UPS will then indicate the current 
sensitivity, as shown in the Transfer Voltage and Sensitivity 
Adjustment
 table below. 
4. To select the LOW sensitivity setting, press the ON/OFF 
push button until the LED begins 
flashing GREEN. 
5. To select the MEDIUM sensitivity setting, press the ON/
OFF push button until the LED begins flashing RED. 
6. To select the HIGH sensitivity setting, press the ON/OFF 
push button until the LED begins 
flashing AMBER. 
7.   To exit Programming mode, once sensitivity is set, wait 
approximately 5 seconds, and all of the LED indicators will 
be off (unlit). 
Indicators
Flashing
Sensitivity Setting
Input Voltage Range
(For Utility Operation)
When to Use
Green
Flashing
LOW
88-142
Input voltage is extremely low or 
high. 
Not recommended for computer 
loads. 
Red Flashing
MEDIUM
(factory default)
92-139
Back-UPS frequently goes on 
battery. 
Amber
Flashing 
HIGH
96-136
Connected equipment is 
sensitive to voltage 
fluctuations.