Place the Back-UPS ES to avoid:
 - Direct sunlight
 - Excessive heat
 - Excessive humidity or contact with fluids
Plug the Back-UPS ES power cord directly into a wall outlet; not a 
surge protector or power strip.
Connect FAX/Modem/Phone
Back-UPS ES protects a single line (2-wire) fax, modem or phone from 
surges when it is connected through the Back-UPS ES as shown.
Connect Computer Cable
The supplied cable and software provide automatic file saving and 
shutdown of the operating system in the case of a sustained power outage.
Connect the cable to the Data Port of the Back-UPS ES. Connect the other 
end of the cable to the USB port on your computer. The software will 
automatically find the USB Port of your computer.
Back-UPS ES 350/550
User Guide
1
2
3
Connect Battery
Connect Equipment
Power On and
Install Software
990-4993A Copyright 2006 American Power Conversion Corporation
All other trademarks are property of their respective owners.
For safety, the Back-UPS ES is shipped with one battery wire disconnected. The Back-UPS ES will not operate until the wire is connected to the touch 
safe battery terminal.  NOTE: Small sparks may occur during battery connection. This is normal.
1
TURN the Back-UPS ES over and 
slide the battery compartment 
cover off of the battery housing.
Surge Protection Only
These outlets provide full-time protection from surges even if 
the Back-UPS ES is switched OFF. Plug your printer, fax 
machine, scanner, or other peripherals that do not need 
battery power into these outlets.
Battery Backup 
Surge Protection
These outlets are powered whenever the Back-UPS ES is 
switched ON. During a power outage or other utility problems 
(brownouts, over-voltages), these outlets will be powered for a 
limited time by the Back-UPS ES. Plug your computer, monitor, 
and two other data-sensitive devices (external disk or tape drive) 
into these outlets.
Press the ON/OFF switch to power the unit 
ON.
A single short beep and the green “Power On” 
indicator confirms that Back-UPS ES is on and 
ready to provide protection.
The Back-UPS ES should charge for at least 
16 hours to ensure sufficient runtime. The unit 
is being charged whenever it is connected to 
utility power, whether the unit is turned ON or 
OFF.
If the red Building Wiring Fault indicator 
(located on the end near the power cord) is lit, 
your building wiring presents a shock hazard 
that should be corrected by a qualified 
electrician.
Install the PowerChute Personal
® 
Edition 
software
Place the PowerChute Personal Edition CD-
ROM into your computer and follow the 
installation instructions on the screen.
2
LIFT the battery out of the compartment and connect the black wire to the negative (-) battery 
terminal. Ensure the batteries are installed as shown below.
APC, the APC logo, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
The Back-UPS ES indicates operating status using a combination of visual and audible indicators. 
Use the following table to identify the status of the Back-UPS ES. 
Status
Visual Indications
(Power On - Green)
(Replace Battery - Red)
Audible Indication
Alarm Terminates 
When
Power On - UPS is supplying conditioned 
utility power to the load.
Power On LED  - ON 
None
Not applicable.
On Battery - UPS is supplying battery 
power to the load connected to the Battery 
outlets.
Power On LED  - ON (off 
during beep)
Beeping 4 times every 
30 seconds
UPS transfers back to 
Power On operation, or 
when UPS is turned off.
Low Battery Warning - UPS is supplying 
battery power to the load connected to the 
Battery outlets and the battery is near 
exhaustion.
Power on LED  - flashing 
Rapid beeping (every 
1/2 second)
UPS transfers back to 
normal operation, or 
when UPS is turned off.
Replace Battery - The battery is 
disconnected.
The battery is in need of charging or is at 
the end of its usual life and must be 
replaced.
Replace Battery LED - 
flashing
Power On and Replace 
Battery LEDs-  Flashing 
(alternating)
Constant tone
Constant tone
UPS turned off with the 
power switch.
Overload Shutdown - During On Battery 
operation a battery power supplied outlet 
overload was detected.
None
Constant tone
UPS turned off with the 
power switch.
Sleep Mode - During On Battery operation 
the battery power has been completely 
exhausted and the UPS is waiting for utility 
power to return to normal.
None
Beeping once every 4 
seconds
Utility power is restored, 
or if utility power is not 
restored within 32 
seconds, or the UPS is 
turned off.
Building Wiring Fault - Your building 
wiring presents a shock hazard that should 
be corrected by a licensed electrician.
Building Wiring Fault LED 
(red) - ON
None
UPS is unplugged, or is 
plugged into a properly 
wired outlet.
Status Indicators
®
See the Troubleshooting section for additional assistance.
Back-UPS ES 550
Slide the battery compartment cover 
completely onto the Back-UPS ES.
3
  Battery Backup      Surge Protection
Surge Protection Only
Power On
Replace Battery
Back-UPS ES
        5 5 0
w
 
w
 
w.apc.com
®
POWER ON/
AC LINE
CORD
TO COMPUTER
USB PORT
FROM WALL JACK
DATALINE OUTPUT TO
DSL MODEM or PHONE
Data Port
Modem/
Phone/Fax
Wall
Outlet
CAUTION - Refer to bottom
    of unit for safety markings.
Circut Breaker
Push to Reset
Building
 Wiring
  Fault
BUILDING WIRING
FAULT INDICATOR
CIRCUIT BREAKER
PUSH TO RESET
REPLACE BATTERY
INDICATOR
Back-UPS ES 350