Hitachi L100 User Manual

Page of 192
L100 Inverter
Getting Star
ted
1–5
L100 Inverter Specifications
Model-specific tables for 200V and 400V class inverters
The following tables are specific to L100 inverters for the 200V and 400V class model 
groups. Note that 
 apply to both voltage class 
groups. Footnotes for all specifications tables follow the table below.
Item
200V Class Specifications
L100 inverters, 
200V models
CE version
002NFE
004NFE
005NFE
007NFE
011NFE
UL version
002NFU
004NFU
007NFU
Applicable motor size  *2
kW
0.2
0.4
0.55
0.75
1.1
HP
1/4
1/2
3/4
1
1 1/2
Rated capacity (240V) kVA *10
0.5
1.0
1.2
1.6
2.0
Rated input voltage
1-phase: 200 to 240V +5/-10%, 50/60 Hz ±5%,
3-phase: 200 to 240V +5/-10%, 50/60 Hz ±5%,
(037LFU, 055LFU & 075LFU 3-phase only)
Rated input 
current (A)
1-phase
3.1
5.8
6.7
9.0
11.2
3-phase
1.8
3.4
3.9
5.2
6.5
Rated output voltage  *3
3-phase: 200 to 240V (corresponding to input voltage)
Rated output current (A)
1.4
2.6
3.0
4.0
5.0
Efficiency at 100% rated output (%)
91.5
92.8
93.6
94.1
95.4
Watt loss,
approximate (W)
at 70% output
13
21
25
31
38
at 100% output
17
29
32
41
51
Braking
Dynamic 
braking, approx. 
% torque, (short 
time stop from 
50 / 60 Hz)  *5
 100%: 
≤ 50 Hz,
50%: 
≤ 60 Hz
Capacitive feedback type, dynamic braking unit and braking 
resistor optional, individually installed
DC braking
Variable operating frequency, time, and braking force
Weight
kg
0.85
0.85
1.3
1.3
2.2
lb
1.87
1.87
2.87
2.87
4.85