Seiko Group BP-6000 User Manual

Page of 114
87
ITEM Mode
Code & Hexadecimal
n: (Hex.) = selection
[33]
Bar code type
Header n n
n:  00=Industrial 2/5,      n: 07=Code 128,
1B, 7C, 60, 02, 00, 6E, n
01=Interleave 2/5,
08=EAN 8,
02=Matrix 2/5,
09=EAN 13,
03=Codabar,
0A=UPC-A,
04=Code 11,
0B=UPC-E,
05=Code 39,
0C=Postnet
06=Code 93,
0D=Element
[34]
Bar code size
Header o n 
n: 00=1
n:
02=2
1B, 7C, 60, 02, 00, 6F, n
01=1.5
03=2.5
[35]
Interface
Header a n
n: 00=Parallel,
1B, 7C, 60, 02, 00, 61, n
01=Serial (RS-232C or RS-422 with optional I/F).
02=Auto
Header a 01 a1 a2 a3 a4 a5
1B, 7C, 60, 07, 00, 61, 01, a1, a2, a3, a4, a5
a1: Parity bit
a1: 00=None,                         a1:02=Even.
01=Odd,
a2: Data length
a2: 00=8 bits,
01=7 bits.
a3: Stop bit
a3: 00=1 bit,
01=2 bits.
a4: Protocol
a4: 00=DTR,                        a4: 02=X-ON/X-OFF (II),
01=X-ON/X-OFF (I),
03=ETX/ACK
a5: Baud rate
a5: 00=1200 Baud,               a5: 02=4800 Baud,
01=2400 Baud,
03=9600 Baud
[36]
Serial error
Header b n
n: 00=Print "*",
1B, 7C, 60, 02, 00, 62, n
01=Ignore.
[37]
Buffer size
Header c n
n: 00=128 bytes,
1B, 7C, 60, 02, 00, 63, n
01=Maximum.
[38]
CSF option
Header j n
n: 00=Not installed,       n:
02=Double bin.
1B, 7C, 60, 02, 00, 6A, n
01=Single bin,
[39]
Factory setting
Header E n
n: FF=Yes.
1B, 7C, 60, 02, 00, 45, n
[40]
Save setup
Header Y n
n: 00=Current,                 n: 02=MEM2,
1B, 7C, 60, 02, 00, 59, n
01=MEM1,
03=MEM3.
[41]
LF SPEED
Header Z n
n: 00=Normal Speed
1B, 7C, 60, 02, 00, 5A, n
01=Half Speed
[42]
CTS, DSR, CD
Header d n1 n2 n3
n1: CTS setting
Setting
1B, 7C, 60, 04, 00, 64, n
n1=00  CTS Disable
(Serial)
n1=01  CTS Enable
n2: DSR setting
n2=00  DSR Disable
n2=01  DSR Enable
n3: CD setting
n3=00  CD Disable
n3=01  CD Enable
[43]
ERROR Status
Header x n
n: 00=ERROR/PE SIGNAL Valid
(Parallel)
1B, 7C, 60, 02, 00, 78, n
01=ERROR/PE Signal invalid
[44]
Invert LCD Display
Header y n
n: 00=Normal LCD Display
1B, 7C, 60, 02, 00, 79, n
01=Invert LCD Display
[45]
Energy Star mode
Header z n
n: 00=Sleep mode valid
1B, 7C, 60, 02, 00, 7A, n
01=Sleep mode invalid
[46]
Reset SW Look
Header F n
n: 00=Reset SW is valid in ONLINE
1B, 7C, 60, 02, 00, 46, n
01=Reset SW is invalid in ONLINE
B.  Control code summary (Setup options)