Seiko Group BP-6000 User Manual

Page of 114
90
ITEM Mode
Code & Hexadecimal
n: (Hex.) = selection
[1]
BAR CODE data
DC4, DC4, B, n
Specifies the numler ("n") of data to be regarded as 
sequence
14, 14, 42, n
bar code data.
0 < n < 44H
[2]
Check digit
DC4, DC4, C, n
Selects/deselects to add a check digit automatically.
14, 14, 43, n
n: 00=No,
01=Yes.
[3]
Element 
DC4, DC4, E, n1, n2
Changes the width of a bar, space, or intercharacter 
variables
14, 14, 45, n1, n2
gap.  n1 specifies the type of element and n2 sets 
variable width in n2/120 inches.
This command is not effective in postnet bar code.
n1: 00=Narrow bar
01=Wide bar
02=Narrow space
03=Wide space
04=Intercharacter gap (ICG)
n2: n2/120" (1
n2
127)
[4]
HRI font
DC4, DC4, F, n
Selects HRI character font.
14, 14, 46, n
This command is not effective in postnet bar code.
n: 00=Current selected font
[5]
Bar code height
DC4, DC4, H, n
Sets bar code height to n/12 inch (1
n
120).
14, 14, 48, n
This command is not effective in postnet bar code.
If n
4, HRI print is disabled.
[6]
HRI print
DC4, DC4, I, n
Selects HRI character not to be printed or to be printed
14, 14, 49, n
below or  above bar code.
This command is not effective in postnet bar code.
n: 00=No print
01=Below bar code
02=Above bar code
[7]
Bar code type
DC4, DC4, T 
Selects a bar code type.
14, 14, 54, n
n: 00=Industrial 2/5,      n:
07=Code 128,
01=Interleave 2/5,
08=EAN 8,
02=Matrix 2/5,
09=EAN 13,
03=Codabar,
0A=UPC-A,
04=Code 11,
0B=UPC-E,
05=Code 39,
0C=Postnet
06=Code 93,
FF=Element
[8]
Guard bar
DC4, DC4, G, n 
Euables/disables the guard bar extension (long bar).
extension
14, 14, 47, n
in EAN and UPC.
n: 00=Disable guard bar extension
01=Enable guard bar extension (default)
[9]
Start/stop char.
DC4, DC4, N, n 
Assigns the start and stop character for the Codabar.
assignment
14, 14, 4E, n
n: 00=Start character
01=Stop character
n: 02={"a", "b", "c", "d", "e", "t", "n", "*"}
Default is "a" as the start and stop character
[10]
Start/stop char.
DC4, DC4, S, n 
Selects to print the start and stop character as HRI for
print
14, 14, 53, n
Codabar, Code 11, Code 39, and Code 93.
n: 00=To print(default)
01=Not to print
[11]
Code 128
DC4, DC, V, n 
Selects code sequence in Code 128 to be treated as a
code sequence
14, 14, 56, n
character value or as a character code.
n: 00=character code(default)
01=character value
[12]
Bar code end
ESC SO
Indicates the end of bar code data sequence.
sequence
1B, 0E
This sequence is valid when 
#27 BAR CODE is to MODE2
in the SUB-MENU of SETUP MODE.
[13]
Bar code start
ESC SI
Treats the following immediate data as a bar code.
sequence
1B, 0F
This sequence is valid when 
#27 BAR CODE is to MODE2
in the SUB-MENU of SETUP MODE.
B.  Control code summary (bar code)