ADC UTU-701C User Manual

Page of 82
700-701-100-02
 Functional 
Description
UTU-701 and ETU-751 List 1
August 9, 2002
 21
 summarizes the equivalent loopbacks for two different activation methods:
LTU and NTU LOC and REM buttons
console screen Test menus (see 
 on 
 for loopback operation from the Test menus)
BER T
ESTING
The HDSL units provide a mechanism for validating circuit integrity utilizing a pseudorandom bit sequence 
(PRBS) generator and BER meter internal to the LTU unit. This diagnostic test disrupts the normal flow of 
payload traffic, and requires the presence of a Network NTU-I/F loopback or an external physical loopback at the 
NTU interface connector. The test is run at the selected HDSL Payload Rate (see 
). BER 
results are accumulated continuously and updated on the console screen at intervals of approximately 16 seconds.
The PRBS data pattern is always generated at the LTU toward the HDSL channel, and the BER is always 
measured at the LTU based on data received from the HDSL channel. The test may be initiated and stopped from 
the Test menu at either the LTU or NTU console screen.
Table 13.
Loopback Equivalents
 
Front Panel
Console Screen Test Menu
Loopback mode
Loopback Position
LTU LOC button
NETWORK 
(a)
LTU-HDSL
LTU REM button
NETWORK
NTU-I/F
NETWORK
LTU-I/F
NTU LOC button
CUSTOMER 
(b)
NTU-HDSL
NTU REM button
CUSTOMER
LTU-I/F
CUSTOMER
NTU-I/F
(a)
 
Activated from console screen Test menu at LTU.
(b) Activated from console screen Test menu at NTU.
The BER test must be stopped before leaving the test menu to restore normal 
payload transmission. Typing 
 
while the BER test is in progress causes the 
following message to display: 
BER Test in Progress. Must STOP 
before leaving screen
.”
ESC